background image

www.Fagorcommercial.com

 

 

PAGE 13 

 

REACH-INS OPERATIONAL SERVICE MANUAL / Rev.JUN. 2015

 

2.

 

Press the up and down arrows to increase or decrease the set temperature. Then press 
the set button to save the new set point. 

 
 
 
 

Note: 
The maximum value you can set in the controller is: For refrigerators: 5°C (40°F) 
For freezers: -16°C (2°F) 

 

3.

 

If you wish decrease the value of the set point for a new temperature, press the button 
DOWN  arrow  (see  the  picture  below).  Press  this  button  to  reach  the  desired  value. 
Release the button and then press the SET button to keep, and save, the new value. 

 

 

Note: 
The minimum value you can set in the controller is: For refrigerators: -1°C (30°F) 
For freezers: -23°C (-8°F) 

 

Changing the reading temperature from °F to °C 

 

To change the reading of the temperature from °F to °C or vice versa, you need access to the 
programming  mode  in  the  controller.  To  do  this,  press  and  hold  the  SET  button  for  five  (5) 
seconds until “PS” is shown in the display. Release the button and press the SET button one 
time. Now you will see the number zero (0). With the button UP arrow, set a value of “22” and 
then press the SET button. You will see the “PS” again. Use the button DOWN arrow to find 
the parameter “EZY” and press the SET button one time. Using the UP or DOWN button set a 
value according to the chart below. 
 

 
 

 

 
 

 
 
 
 
 
 
 
 
Note: 

For Refrigerators

 

EZY Value

 

Application

 

Temperature in °F 

Refrigeration 

Temperature in °C 

Refrigeration 

 

For Freezers

 

EZY Value

 

Application

 

Temperature in °F 

Freezer 

Temperature in °C 

Freezer 

Temperature in °F 

Refrigeration 

Temperature in °C 

Refrigeration 

 

Summary of Contents for QF-1

Page 1: ...REFRIGERATORS AND FREEZERS Manual for installation use and maintenance...

Page 2: ...6 3 3 DATA PLATE 7 3 4 INSTALLATION OF CASTORS OR OPTIONAL LEGS 7 3 5 LEVELING 9 3 6 ELECTRICAL CONNECTIONS 9 3 7 SHELVING INSTALLATION 10 4 OPERATION 10 4 1 ELECTRONIC CONTROL 10 4 2 OTHER FUNCTIONS...

Page 3: ...aterial until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines ar...

Page 4: ...3 1666 11 3 R 134a 295 QR 2 49 6 2104 13 4 R 134a 475 QF 1 23 3 2493 16 6 R 404A 295 QF 2 49 6 3644 21 5 R 404A 475 QR 1G 23 3 1666 11 3 R 134a 295 QR 2G 49 6 2104 13 4 R 134a 475 QVR 1 21 3 1666 11 3...

Page 5: ...QVR 1 5 6 3 1 1 4 115 220 5 15P 2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 12 AWG 10 AWG 12 AWG QVR 2 6 9 3 5 1 3 3 8 115 220 5 15P 2P TT 15 amp 10 amp 14 AWG 14 AWG 1...

Page 6: ...THE MACHINES NEEDS TO BE INSTALLED 2 FEET AWAY FROM ANY HEAT SOURCES The unit should not be installed under ambient temperatures higher than 100 F If the relative humidity is higher than 60 the door...

Page 7: ...The data plate is essential to identify the particular features of your machine and it is of great benefit to installers operators and maintenance personnel It is recommended that in the event the da...

Page 8: ...shims between the castor and the frame rail Install the desired number of shims Make sure the slot of the shim is in contact with the threaded stem of the castor FIG 2 If more than one shim is used t...

Page 9: ...l code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information Do not under any circumstances cu...

Page 10: ...rly 4 OPERATION 4 1 ELECTRONIC CONTROL After connecting your unit turn ON rocker switch located next to the controller The display will light up showing the temperature inside the unit Also the compre...

Page 11: ...www Fagorcommercial com PAGE 11 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015...

Page 12: ...hanging the set point of the temperature on the controller The unit comes with a factory default set point 8 F Freezers 32 F Refrigerators These set values will make the unit perform at its maximum ca...

Page 13: ...anging the reading temperature from F to C To change the reading of the temperature from F to C or vice versa you need access to the programming mode in the controller To do this press and hold the SE...

Page 14: ...exit manual defrost hold the DOWN button arrow for 5 seconds The snow flake icon will turn off Wait 2 minutes for the compressor to start Note If the equipment doesn t reach the temperature first ver...

Page 15: ...rs Type F parameters include the set point differential temperature monitoring interval interval between defrosts end defrost temperature dripping time alarm thresholds alarm bypass times etc See the...

Page 16: ...the Parameter belongs to see the table below and the parameter table 5 Press the SET button to display the value of the parameter 6 Press UP DOWN until reaching the desired value 7 Press Set to tempor...

Page 17: ...y food products have an acidic content which can deteriorate the stainless steel finish Be sure to clean ALL food products from any stainless steel surface Failure to do so will result in spots and ru...

Page 18: ...tom panel 5 3 GASKET Gaskets require regular cleaning to prevent mold and mildew build up and to keep the elasticity of the gasket Gasket cleaning can be done with the use of warm soap and water Avoid...

Page 19: ...with the drain hose inside of the pan Units installed in a humid environment will produce large amounts of water in the drain pan This is NOT a malfunction of the unit It is the customer s responsibil...

Page 20: ...e maximum level mark located on the internal wall of the unit f If FREEZER check that the temperature is not Celsius C g Check that the gasket is in good condition and door is sealed h Check that the...

Page 21: ...www Fagorcommercial com PAGE 21 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 7 WIRING DIAGRAMS QR 1 QVR 1...

Page 22: ...www Fagorcommercial com PAGE 22 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QF1 QVF 1...

Page 23: ...www Fagorcommercial com PAGE 23 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QR2 QVR 2...

Page 24: ...www Fagorcommercial com PAGE 24 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 QR 1G QVR 1G...

Page 25: ...ill be replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warran...

Page 26: ...waived unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have the...

Page 27: ...n deliveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted an...

Page 28: ...w Fagorcommercial com PAGE 28 REACH INS OPERATIONAL SERVICE MANUAL Rev JUN 2015 Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 GO FAGOR www fagorcommercial c...

Reviews: