Fagor MK Series Manual Download Page 8

Page 8/8 - "MK" - V1106

DECLARATION OF CONFORMITY

Manufacturer:    Fagor Automation, S. Coop.

Barrio de San Andrés s/n, C.P. 20500, Mondragón -

Guipúzcoa- (SPAIN)

We declare under our exclusive responsibility the
conformity of the product referred to in this manual.

Note.  Some additional characters may follow the model
references indicated in this manual. They all comply with
the following regulations:

ELECTROMAGNETIC COMPATIBILITY:

EN 61000-6-2:2005 Standard on immunity in industrial

environments

EN 61000-6-4:2007 Standard on emission in industrial

environments

According to the European Directive:

2004/108/CE on electromagnetic compatibility.

DECLARACION DE CONFORMIDAD

Fabricante:    Fagor Automation, S. Coop.

Barrio de San Andrés s/n, C.P. 20500, Mondragón -

Guipúzcoa- (ESPAÑA)

Declaramos bajo nuestra exclusiva responsabilidad la
conformidad del producto al que hace referencia este
manual

Nota. Algunos caracteres adicionales pueden seguir a
las referencias de los modelos indicados en este manual.
Todos ellos cumplen con las siguientes normas:

COMPATIBILIDAD ELECTROMAGNÉTICA:

EN 61000-6-2:2005 Norma de Inmunidad en entornos

industriales

EN 61000-6-4:2007 Norma de Emisión en entornos

industriales

De acuerdo con las disposiciones de la Directiva
Comunitaria:
2004/108/CE de Compatibilidad Electromagnética.

Mondragón a 1 de Septiembre de 2009

Mondragón September 1st 2009

Fagor Automation S. Coop.
Bº San Andrés Nº19
Apdo Correos 144
20500 - Arrasate/Mondragón

- Spain -

Web: www.fagorautomation.com
Email: [email protected]
Tel.: (34) 943 719200
Fax: (34) 943 791712

The information described in this manual may be
subject to variations due to technical modifications.

FAGOR AUTOMATION, S. Coop. Ltda. reserves the
right to modify the contents of this manual without
prior notice.

* Term: 12 months from factory invoice date.
* It covers parts and labor at FAGOR AUTOMATION.
* Travel expenses are payable by the customer.
* Damages due to causes external to FAGOR

AUTOMATION, such as unauthorized manipulation,
blows, etc. are not covered.

WARRANTY

La información descrita en este manual puede estar
sujeta a variaciones motivadas por modificaciones
técnicas.

FAGOR AUTOMATION S. Coop. Ltda. se reserva el
derecho de modificar su contenido, no estando
obligada a notificar las variaciones.

* 12 meses desde fecha de expedición de fábrica.
* Cubre gastos de Materiales y Mano de Obra de repa-

ración en FAGOR AUTOMATION.

* Gastos de desplazamiento a cargo del cliente.
* No cubre averías por causas ajenas a FAGOR

AUTOMATION, como: golpes, manipulación por per-
sonal no autorizado, etc.

GARANTIA

Summary of Contents for MK Series

Page 1: ...MANUAL CODE 14460009 MANUAL VERSION V1106 LINEAR ENCODERS MK Model REGLAS Modelo MK Fagor Automation ...

Page 2: ...Page 2 8 MK V1106 DIMENSIONES DIMENSIONS For para ML 520 mm ...

Page 3: ...V1106 MK Page 3 8 POSIBILIDADES DE MONTAJE MOUNTING POSSIBILITIES 15 5 15 5 ...

Page 4: ...in mind its useful travel and the minimum bending radius R of the cable Soltar el tornillo de fijación que se utiliza para el transporte del transductor Unscrew the shipping protection screw of the scale Montar el transductor Mount the scale Posicionamiento de los relojes comparadores Positioning of the dial indicators Alinear las caras del transductor realizando mediciones en los extremos y en el...

Page 5: ... impedancia existente entre el conector y el transductor es inferior a 1 Ohmio Verify that the impedance between the connector and the scale is less than 1 Ohm Es conveniente colocar sistemas de protección ante posibles caídas de líquidos materiales etc It is recommended to mount some kind of protection cover as to avoid damage caused by materials or liquids falling onto the scale ...

Page 6: ...emperature 0 C 50 C 32 F 122 F Storage temperature 20 C 70 C 4 F 158 F Relative Humidity 20 80 Weight 0 58kg 0 6kg m Scale 20 µm pitch graduated glass Standard cable Length 3 m For other models the number indicates cable length in meters For example MKX1 1m cable Cable bending radius 75 mm Reference mark Standard One reference mark approximately in the middle of the measuring length From there one...

Page 7: ...0 and their inverted pulse trains A B Marker pulse Io and their inverted pulse Io MKX model Synchronized with A and B signals Period T of feedback signals 4 µm Period of marker pulse Io T 4 MODELO MKX Tensión de alimentación 5 V 5 150 mA Longitud de cable permitida Con señales diferenciales 50 mts máximo Se debe utilizar cable de 8x0 14 2x0 5 mm2 Con modelos que no sean Fagor la longitud del cable...

Page 8: ...os industriales De acuerdo con las disposiciones de la Directiva Comunitaria 2004 108 CE de Compatibilidad Electromagnética Mondragón a 1 de Septiembre de 2009 Mondragón September 1st 2009 Fagor Automation S Coop Bº San Andrés Nº19 Apdo Correos 144 20500 Arrasate Mondragón Spain Web www fagorautomation com Email info fagorautomation es Tel 34 943 719200 Fax 34 943 791712 The information described ...

Reviews: