7
2 CHARACTERISTICS
MODEL
HVG-10/11
HVG-10/21
HVG-2-10/11
HVG-20/11
HVG-20/21
HVG-2-20/11
Width X
1060
1180
1060
1180
Depth Y
965
1170
965
1270
Height without chimney W
925
925
1635
1635
Height with chimney Z
1290
1290
2000
2000
Width U
650
770
650
770
Depth V
535
740
535
740
EXTERNAL
DIMENSIONS
mm
Depth Gas R
600
800
600
900
Net weight (Kg.)
210
275
320
430
Electrical power Kw
0.4Kw
0.4Kw
0.6Kw
0.6Kw
Hose
section
2x1,5+T
Fuse Int.
General
10ª
Supply
voltage
220-240V
1N
50-60Hz
Differential
Device
30Ma
Kcal/h (Hs)
34,400
39,560
44,720
72,240
BTU (Hs)
136,500
157,000
177,500
286,700
Gas power
Kw. (Hi)
40,000
46,000
52,000
84,000
Kg/h (29mb)Butane (G-30)
3,330
3,830
4,330
6,990
Kg./h (37 mb) Propane (G-31)
3,280
3,770
4,265
6,890
m³./h (20 mb) Natural gas (G-20)
4,235
4,870
5,500
8,890
m³./h (25 mb) Natural gas (G-25)
4,555
5,170
5,665
9,840
m³./h (8 mb) City gas (G-110)
000
000
000
000
m³./h (8 mb) City gas (G-130)
000
000
000
000
Nominal
consumption
m³./h (8 mb) City gas (G-150)
000
000
000
000
Hot air
90
90
90
90
Performance %
Steam (%)
85
85
85
85
GN 1-1
10
20
20
40
Max. no. trays
GN 2-1
-
10
-
20
Maximum load weight in kg
50
100
100
200
Approximate water consumption (litres/hour)
30
30
30
50
Water inlet pressure Kg/cm
0.5---8
Summary of Contents for HVG-10/11
Page 1: ...TECHNICAL MANUAL GAS OVENS HVG and HCG NOVEMBER 2001 FAGOR Industrial S Coop...
Page 3: ...3 1 MODELS AND DIMENSIONS fig 1 fig 2...
Page 4: ...4 fig 3...
Page 5: ...5 fig 4 fig 5...
Page 25: ...25 HVG SIDE VIEW OF ELECTRICAL COMPONENTS fig 38 Gas intake Electrical wiring connection inlet...
Page 26: ...26 HVG REAR VIEW fig 39 Soft water connection...
Page 28: ...28...
Page 29: ...29 fig 40...
Page 30: ...30 fig 41...
Page 31: ...31 fig 42...
Page 32: ...32 fig 43...
Page 56: ......
Page 57: ...57...