PROCEDURE TO INSTALL EXTERNAL CHEMICAL PUMP
A) ELECTRICAL CONNECTIONS
Wiring kit must be supplied from Fagor to make the electrical
connections. Contact 1 866 - GO FAGOR (463-2467) to be
supplied with one.
One side of the wiring kit has three caps (White, Violet and
Green) with jumpers. The other side has 4 bare wires (White,
Violet and (2) Greens)
PROCEDURE to connect the wiring kit:
Connect the Green Cap of the wiring kit in the terminal block with the blue caps. FIG.1
Connect the Violet Cap of the wiring kit in the firt position of the selector switch. FIG.2
Connect the White Cap of the wiring kit in the second position of the timer (M2), third row, together
with the yellow cap of the timer
The other side of the wiring kit remains the 4 bare wires. Connect Violet and Green Wires into the
Detergent Pump. Pump will have voltage during the wash cycle. Connect White and Green Wires into
the Rinse Pump. Pump will have voltage during rinse cycle.
FIG.
1
FIG.2
FIG.
3
B) INJECTORS CONNECTIONS
External Detergent Injector must be installed above the stainless steel
scrap filters.
Remove black hose connected to the current rinse dispenser. Connect
External Rinse Injector into the black hose