background image

 

 

 

LIMITED WARRANTY 

One  Year  Parts  &  Labor  Warranty:

 

Fagor  Commercial,  Inc.  (“Fagor”)  warrants  to  the  first-end-user  purchaser  (the 

“User”) that the Fagor brand equipment sold hereunder, except for parts and accessories which carry the warranty of a 
supplier (the “Equipment”) will be free from defects in material and factory workmanship under normal conditions of use 
and  maintenance  for  a  period  of  (1)  one  year  from  the  date  of  Installation  (Warranty  Commencement  Date),  but  in  no 
event to exceed (15) fifteen months from the date of shipment.   

Warranty Coverage: 

If there is a defect in material or factory workmanship covered by this Warranty reported to Fagor 

during the period the applicable Warranty is in force and effect, Fagor will repair or replace, at Fagor’s option, that part of 
the  Equipment  that  has  become  defective.    Fagor  will  cover  labor  cost  within  one  year  from  the  Warranty 
Commencement  date  or  15  months  from  shipment  date,  whichever  occurs  first.    Fagor  shall  bear  all  labor  costs  in 
connection  with  the  installation  of  these  replacement  parts,  provided  that,  the  installation  is  conducted  by  Fagor  or  its 
authorized  representative.    Charges  for  warranty  travel  time  to  round  trip  total  (2)  two  hours  or  up  to  100  miles.    Any 
charges exceeding those stated herein must have prior authorization by Fagor. In case Fagor deems the equipment non-
repairable,  said  equipment  will  be  replaced  and  the  replacement  unit(s)  will  carry  the  same  warranty  period  from  the 
original unit’s installation date (Original Warranty Commencement Date).  

 

Exclusions from and Conditions to Warranty Coverage: 

This Warranty does not cover parts or accessories, which (a) 

carry the warranty of a supplier or (b) are abused. Application of this Warranty is further conditioned upon the following:  

 

Installation.  The  Equipment  m

ust be properly installed in accordance with Fagor’s installation procedures and 

instructions and reviewed and tested by a professional technician.  

 

No Alteration.   The Equipment must not have been modified or altered from its condition at the date of original 

installation.  

 

Use.  FAGOR  EQUIPMENT  IN  NOT  DESIGNED  FOR  PERSONAL,  FAMILY  OR  HOUSEHOLD  PURPOSES, 

AND ITS SALE FOR SUCH PURPOSES IS NOT INTENDED.  IN THE EVENT THE EQUIPMENT IS SO USED, THIS 
WARRANTY  SHALL  BE  NULL  AND  VOID,  AND THE  EQUIPMENT  SHALL  BE  D

EEMED TO HAVE BEEN SOLD “AS 

IS-

WHERE IS” WITHOUT ANY WARRANTY OF ANY KIND, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF 

TITLE, NON-INFRINGEMENT, MERCHANT-ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  

 

Water Quality. Water supply should have hardness between .25 and 3.0 grains per gallon, pH level between 6.5 

–  7.5  and  TDS  level  less  than  60  PPM.    Equipment  failure  due  to  inadequate  water  supply  is  not  covered  by  this 
Warranty.  

 

Proper Maintenance and Operation. The Equipment must be properly maintained and operated in accordance 

with  Fagor’s  maintenance  and  operating  procedures.    All  service,  labor  and  parts  must be  acquired  from  Fagor  or  its 
authorized service representative for the User’s area.  

 

Minor  Parts.  No  labor  will  be  associated  with  the  replacement  of  minor  items  such  as,  and  not  limited  to, 

switches, pilot lights, gauges, fuses, etc. or replacement of wear items such as curtains, squeeze tubes, etc.  

 

This warranty is void if failure is a direct result of handling &/or transportation, fire, water, accident, misuse, acts 

of God, attempted repair by unauthorized persons, improper installation, if serial number has been removed or altered, or 
if unit is used for purpose other than it was originally intended.  

 

Failure to comply with any of these conditions will void this Warranty.  In addition, this Warranty does not cover defects 
due to apparent abuse, misuse or accident.  

Fagor will have no responsibility to honor claims received after the date the applicable Warranty expires. Notwithstanding 
the foregoing, any claim with reference to the Equipment or any parts therefore for any cause shall be deemed waived 
unless  submitted  by  the  User  to  Fagor  within  thirty  (30)  days  after  the  date  the  User  discovered,  or  should  have 
discovered, the claim.

 

In connection with all claims under this Warranty, Fagor will have the right, at its own expense, to 

have its representatives inspect the Equipment at the User’s premises and to request all of User’s records pertaining to 
the  Equipment  to  determine  whether  a  defect  exists,  whether  the  conditions  set  forth  in  this  Warranty  have  been 
satisfied, and whether or not the applicable Warranty is in effect.  

 

THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES NOT EXPRESSLY SET 
FORTH HEREIN, WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING BUT 
NOT LIMITED TO ANY REPRESENTATION OF PERFORMANCE AND ANY IMPLIED WARRANTIES OF TITLE, NON-
INFRINGEMENT,  MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.   NO OTHER WAR-RANTIES 
ARE AUTHORIZED ON BEHALF OF FAGOR UNLESS SPECIFICALLY ISSUED BY FAGOR.   

Fagor shall have no liability for incidental or consequential losses, damages or expenses, loss of sales, profits 
or goodwill, or punitive or exemplary damages directly or indirectly arising from the sale, handling or use of the 
Equipment or from any other cause relating thereto, whether arising in contract, tort, warranty, strict liability or 
otherwise.  Fagor’s  liability  hereunder  in  any  case  is  expressly  limited,  at  Fagor’s  election,  to  repair  or 
replacement of Equipment or parts therefore or to the repayment of, or crediting the user with, an amount equal 
to the purchase price of such goods.

 

 

Summary of Contents for Evo CO-402 W

Page 1: ...GENERAL INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE W MODELS MOD COP 174W COP 504 W CO 502 W CO 402 W CODE 12119601 REV 04 2015 Hood type Dishwasher Undercounter Dishwasher Glasswasher...

Page 2: ...MANUAL WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE I...

Page 3: ...PPM Equipment failure due to inadequate water supply is not covered by this Warranty Proper Maintenance and Operation The Equipment must be properly maintained and operated in accordance with Fagor s...

Page 4: ...ressure pump 20 8 10 Recycling 20 9 USE AND MAINTENANCE INSTRUCTIONS 21 9 1 Operation 21 9 1 1 Control panel symbols 21 9 1 2 Switching on the machine 21 9 1 3 Preparation of the dishes 22 9 1 4 Selec...

Page 5: ...2 GENERAL MEASUREMENTS AND CONNECTIONS Hood type Dishwasher COP 174W A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Terminal Box Rinse aid inlet Detergent inlet Equipotential bo...

Page 6: ...6 Undercounter Dishwasher CO 502 W COP 504 W Glasswasher CO 402 W A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Terminal Box Rinse aid inlet Detergent inlet Equipotential bond...

Page 7: ...7 3 QUICK STARTUP GUIDES...

Page 8: ...8...

Page 9: ...9 4 ELECTRICAL DIAGRAM...

Page 10: ...MB2 Wash Pump Pompe de lavage P1 Tank Pressure switch Pressostat de cuve P2 Drain pump Pressure switch Pressostat de Pompe de vidange P3 Boiler Pressure switch Pressostat de surchauffeur PP2 Soft Star...

Page 11: ...ny other objects must not be washed in the machine If your machine breaks down please call the Technical Service Centre Unqualified or unauthorised personnel must NOT try to repair the machine Use of...

Page 12: ...25psi 5psi CO 402W 22 242 352 4 0 6 WASH MIN TEMP HEATING ELEMENTS OPERATING CYCLE TIME s MODEL PUMP MOTOR WASH RINSE WASH TANK kW BOILER kW WASH DWELL RINSE TOTAL COP 174W 2 1 hp 162 F 4 75 12 75 35...

Page 13: ...38 5 07 2 36 0 49 2 29 4 58 COP 504W 60Hz 220V 25 78 5 67 2 50 0 55 4 12 5 12 Boiler Full Power 1Ph 240V 28 13 6 75 2 72 0 65 4 90 6 10 208 240V 208V 17 04 3 54 2 36 0 49 2 29 3 05 COP 504W 60Hz 220V...

Page 14: ...juries 8 1 Removal of packaging Remove packaging from the machine and check for damage during transportation If any damage is observed immediately notify the supplier and the transport company In the...

Page 15: ...e appliance between the power supply and the appliance in accordance to required consumption guidelines Switch the circuit breaker to OFF when servicing the appliance It is recommended that it has loc...

Page 16: ...chine Adaptor supplied for female garden hose connection FOR HARD WATER SUPPLIES WITH A HARDNESS OF OVER 3 gpg OR 5 fH AND PH BEYOND THE RANGE OF 6 5 7 5 A WATER CONDITIONER DESCALER MUST BE INSTALLED...

Page 17: ...therefore the drainage pipe should be lower than the drainage outlet Fig 5 If the drainage pipe is not lower a drainage pump will be required This must not be mounted at a height of more than 26 3 4...

Page 18: ...Electric rinse aid dispenser COP MODELS Installation Take the tube located in the back or your machine marked Rinse Aid and place inside rinse container Tubes are transparent to provide you visible m...

Page 19: ...mended that the rinse aid product and the dispenser setting are defined by a technician specialised in the use of chemical products in order to ensure a more efficient wash 8 8 Detergent dispenser Thi...

Page 20: ...machine may operate incorrectly The electrical connections for the pressure pump are shown in the electric circuit diagram The water connection to the pressure pump is shown in Fig 4 If the mains wate...

Page 21: ...he water inside the machine is not yet at the ideal temperature When the machine has reached the ideal temperature for washing the dishes properly a light comes on advising the user that the machine i...

Page 22: ...dishwasher prior to your boiler reaching a minimum of 180 F 83 C YOU WILL HAVE AN EXTENDED WASH CYCLE 9 1 4 1 Thermo stop The thermo stop is designed to ensure a constant rinse at the maximum tempera...

Page 23: ...machine if the day is completed Leave door open until the next day s operations or to one of the time settings to begin using the machine again To avoid the risk of damage from oxidization or corrosio...

Page 24: ...etergents suitable for industrial dishwashers Do not use foam producing detergents Detergents designed for domestic use should not be used under any circumstances When handling chemical substances the...

Page 25: ...s obstructed Clean distributors thoroughly Shortage of detergent Call the technical service to reset the dispenser Dirty filters Clean the filters thoroughly Presence of foam Unsuitable detergent Call...

Page 26: ...chnical characteristics with prior warning 10 1 Error diagnosis ERROR DESCRIPTION CONSEQUENCE 1 DOOR OPEN The ON OFF LED lights up for 0 5 seconds and then remains unlit for 2 seconds before lighting...

Page 27: ...ure probes The alarm is shown on the corresponding display tank temperature display or boiler temperature display A4 Temperature probe open alarm Verify proper connections at the circuit board and pro...

Page 28: ...Fagor Commercial Inc 13105 NW 47th Avenue Miami FL 33054 USA T 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com...

Reviews: