02/05/2020
36
SERVICE MANUAL
CONVEYOR BELT
DISHWASHERS
Fig. 13
Connection strip
DE
(Fig. 3/Fig. 4
).
Connection A
1 / 2
Tube fill and rinse active signal.
Connection B
1 / 3
Rinse active signal.
Connection C
1 / 4
Wash pump active signal.
Connection D
1 / 5
Electrical connection at 230 V 1N~ (max.
1A) when the appliance is on.
Connection
Earth.
Connection E
6 / 5
Connection for extra emergency button.
Connection F
7 / 5
Limit switch connection.
On completion of the electrical connection, the cover of the electric panel must be replaced and secured.
19.9.
LIMIT SWITCH/MICRO SWITCH
The limit switch/micro switch is mounted at the end of the dishwasher output bench, where it is activated when the
basket reaches the end of the bench, and the machine operation is stopped. When the limit switch is released on
removing the baskets from the bench, the machine continues with the wash.
The electrical connection cables of the limit switch / micro switch must be inserted through the packing gland
DSR
(Fig. 3/Fig. 4
) and connected to the
DE
terminal strip at
connection
7 / 5 as with the dispensers (see
Fig.13
.).
On completion of the electrical connection, the cover of the electric panel must be replaced and secured.
19.10.
EXTRA EMERGENCY BUTTON
The appliance also permits the installation of an extra external emergency button in the location required.
The electric connection cables must be inserted through the
DSR
packing gland and connected to the
DE
terminal strip
at
connection
6 / 5 as with the dispensers.
On completion of the electrical connection, the cover of the electric panel must be replaced and secured.
20.
SAFETY LOCKING SYSTEM
The machine is fitted with a safety locking system, which stops the appliance and notifies the user with a light and
acoustic signal if a blockage or impediment is detected in the feed system.
This system must be adjusted if the dishwasher has accessories such as automated input and/or output benches
which require a greater feed force than the force configured as standard, as a greater weight is carried on the belt.
If the dishwasher has automated input and/or output benches which require
a greater feed force, the spring supplied in the kit must be installed.
The additional spring must not be installed without checking that it is really
necessary, as this could damage the appliance.
To adjust the system first disconnect the water using the shut-off valve, and then the electricity, using the magneto-
thermal switch/ setting the mains switch
IG
to
OFF
.
Summary of Contents for Eco Concept CCO-120
Page 1: ...CONVEYOR DISHWASHERS Service Manual SERVICE MANUAL CONVEYOR DISHWASHERS 02 05 2020...
Page 13: ...02 05 2020 12 SERVICE MANUAL CONVEYOR BELT DISHWASHERS 11 USE...
Page 19: ...02 05 2020 18 SERVICE MANUAL CONVEYOR BELT DISHWASHERS 15 TECHNICAL DATA...
Page 20: ...02 05 2020 19 SERVICE MANUAL CONVEYOR BELT DISHWASHERS...
Page 57: ...02 05 2020 56 SERVICE MANUAL CONVEYOR BELT DISHWASHERS...
Page 67: ...02 05 2020 66 SERVICE MANUAL CONVEYOR BELT DISHWASHERS...
Page 71: ...02 05 2020 70 SERVICE MANUAL CONVEYOR BELT DISHWASHERS...
Page 75: ...02 05 2020 74 SERVICE MANUAL CONVEYOR BELT DISHWASHERS 36 ELECTRICAL DIAGRAM...
Page 76: ...02 05 2020 75 SERVICE MANUAL CONVEYOR BELT DISHWASHERS...