Connection diagrams
10.
358
Ref.1912
DDS
HARDWARE
· 350 ·
Diagram for general connection to mains
F. H10/23
ACD/SCD compact drive, SERCOS. Diagram for general connection to mains.
PE
- S1
MECHANICAL
MAIN SWITCH
- F1
- F2
- F3
MAIN FILTER 42A-A
L1
L1
L2
L3
3x 200-240 VAC
2x 200-240 VAC
L1
CONTACTOR
- KM1
L2
- Q1
DIFFERENTIAL
BREAKER
WARNING.
When using an isolating transformer, the secondary must be
connected in star and its middle point must be connected to GND.
POWER MAINS
IT A MUST TO USE FUSES
TO THE X1
CONNECTOR
ACD/SCD COMPACT
DRIVES
TO THE POWER CONNECTOR
ACD/SCD COMPACT DRIVES
L2
L3
N
R
S
T
3x 200-240 VAC
48 ... 62 Hz
PE
- S1
MECHANICAL
MAIN SWITCH
- F1
- F2
- F3
MAIN FILTER 42A-A
L1
L1
L2
L3
3x 400-460 VAC
2x 400-460 VAC
L1
CONTACTOR
- KM1
L2
- Q1
DIFFERENTIAL
BREAKER
WARNING.
When using an isolating transformer, the secondary must be
connected in star and its middle point must be connected to GND.
POWER MAINS
IT A MUST TO USE FUSES
TO THE X1
CONNECTOR
ACD/SCD COMPACT
DRIVES
TO THE POWER CONNECTOR
ACD/SCD COMPACT DRIVES
L2
L3
N
R
S
T
3x 400-460 VAC
48 ... 62 Hz
Line voltage: 400 (1-10 %) V AC / 460 (1+10 %) V AC
Line frequency: 48 ... 62 Hz
Line voltage: 200 (1-10 %) V AC / 240 (1+10 %) V AC
Line frequency: 48 ... 62 Hz
Note.
Observe that having the main key -S1 closed, although the power contactor - KM1 is open, the internal
24 auxiliary power supply of the unit remains connected through its connector X1 to feed the control circuits of
the drive.
Summary of Contents for DDS APS-24
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......