Functional safety
328
9.
FUN
C
TI
ON
AL SAFET
Y
Response time of
the safety
func
tions
Ref.1912
DDS
HARDWARE
· 322 ·
9.8 Response time of the safety functions
Response time of the safety functions of the machine
The standard EN ISO 13849-1 requires the machine safety manual to report
the response time of the safety functions implemented in the machine. These
measurements must be taken from the instant the danger condition takes
place (e.g. door opened) to the instant the safety function is executed (e.g.
machine stopped). This time will depend on the design of the machine's safety
control circuit.
Response time of the safety functions of the drive
The table below provides the response times of the safety functions of the
AXD/SPD.
Actual response time of the holding brake
Consider that the actual response time of the holding brake is the sum of the
response time of its control and the response time of the brake itself which
for FAGOR brakes varies between 5 and 30 ms.
T. H9/3
Response time of the safety functions of the AXD/SPD.
time
Comment
STO:
- KM1
external
channel
Depends
on used
- KM1
contactor
Measurement taken with a Schneider
contactor. The system delay between the
actual opening of the contacts and the “Torque
Off” is less than 35 ms.
STO:
Drive Enable
integrated
channel
< 15 ms
Measurement taken in a circuit equivalent to
that of figure
with a external safety
c o n t r o l l e r f o r e m e r g e n c y s t o p f r o m
Telemecanique. The delay of the internal circuit
is less than 15 ms.
Summary of Contents for DDS APS-24
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......