5. Setting the Brake ON/OFF Timing When Servomotor Running.
The following parameters can be used to change the /BK signal output conditions when a stop reference
is output during servomotor operation due to the servo OFF or an alarm occurring.
4.3.5. Instantaneous Power Loss Settings
Determines whether to continue operation or turn the servo OFF when the power supply voltage to the
servodrive main circuit is instantaneously interrupted.
Pn507
Brake Waiting Speed
Speed
Setting Range
Setting Unit
Factory Setting
Setting Validation
10 ~ 100
1 rpm
100
Immediately
Pn508
Brake Waiting Time
Speed
Setting Range
Setting Unit
Factory Setting
Setting Validation
10 ~ 100
10 ms
50
Immediately
/BK Signal Output Conditions When Servomotor Running
The /BK signal goes to high level (brake ON) when either of the following conditions is satisfied:
- When the servomotor speed falls below the level set in Pn507 after servo OFF.
- When the time set in Pn508 is exceeded after servo OFF.
Parameter
Signal Name and Meaning
Pn000
b.0
Continue operation when the power supply voltage to servodrive main circuit is
instantaneously interrupted.
b.1
An alarm occurs when the power supply voltage to servodrive main circuit is
instantaneously interrupted.
Summary of Contents for BCSD Series
Page 1: ...SYSTEM BCSD User manual Ref 1809...
Page 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Page 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Page 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Page 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Page 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Page 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Page 117: ......