8

7. WARNING: DO NOT OVERLOAD

THE SCALES

If the load capacity is exceed by 1%, the
scales may be damaged and the following
warning will appear on the display:

1.

Adjust the scales as described above.

2.

Weigh the first article. If you wish to add
further articles, press         to set the
scales to 

0

:

3.

You can now place any additional articles
to be weighed in the bowl, repeating
these last two steps if you wish. The net

8. BATTERY LOW INDICATOR

When the battery needs replacing, the
following message will appear on the
display: 

When this happens, follow the adjustment
instructions. 

Remember that batteries are
not household waste. Spent
batteries must be disposed of
in the special containers
provided.

9. USING THE TARE BUTTON (4)

6.

Make sure that the scales show "zero"
weight before starting to weigh. If not,
press the tare button to reset (4).

7.

If the scales are not used, they will
automatically switch off after 1 minute.
You can also switch them off manually
by pressing the         button. 

weight of the additional article will appear
on the display:

4.

If you remove an article from the bowl,
a negative value (-) will appear. This
represents the weight of the article you
have removed. 
Press the         button again each time
you remove an article, to set the
reading to 0 again:

NOTE:

When you activate the scales

for the first time, if no reading appears
or if the reading does not stabilise at 0,
you can also press the        button.

a.

Switch on the scales by pressing the
button.   

b.

Press the       button. A bell (      ) will
appear at the top left of the display.

c.

Press 

or 

to programme the

desired time lapse. Each time 

or 

is

pressed, the time interval will increase
or decrease by 10 seconds.

d.

Press the         button again to start the
countdown.

e.

When the timer reaches "

00:00

", the

alarm buzzer will sound. The buzzer will
sound 30 times and then automatically
switch off.

f.

To stop the alarm buzzer, press the
button to switch off the scales.

g.

To stop the countdown, press the
button. To reprogramme it, press it
again.

10. ALARM TIMER

interior    8/3/06  10:35  Página 7

Summary of Contents for BC-200

Page 1: ...ndern Il fabbricante si riserva il diritto a modificare i modelli descritti in questo Manuale d Istruzioni O k t ÛkÂv Ût ç È tËp okÏÂÈÛtÈk to Èk ˆÌ v tpo o oÈ Û t Ìovt Ï ou ÂpÈyp ºovt È Ûto pfiv Evtu o O ËyÈÒv A gyártó fenntartja magának a jogot a használati útmutatóban közölt műszaki adatok megváltoztatására Výrobce si vyhrazuje právo modifikovat modely popsané v tomto uživatelském návodu Výrobc...

Page 2: ...l botón Kg lb para seleccionar la unidad de medida que desee en lb o en Kg Nota Cuando encienda la balanza aparecerá la unidad utilizada en la anterior pesada 4 Según se haya seleccionado en gramos o en libras en la pantalla se visualizará lo siguiente a en kilogramos b en lb 5 La balanza ya está preparada para pesar Intente mantener el objeto a pesar en el centro del bol Lea la pantalla cuando la...

Page 3: ...asa la capacidad de carga en un 1 puede provocar daños en la balanza y la pantalla comenzará a indicar el mensaje de aviso Que equivale a 65 gr 6 Asegúrese de que la balanza muestra cero como peso antes de realizar la pesada Si no es así pulse el botón tara 4 7 Cuando no se realiza ninguna pesada en un máximo de 1 minuto la balanza se desconectara automáticamente También puede desconectar manualme...

Page 4: ...íodo largo 2 No presione el pulsador muy fuerte o con objetos punzantes como la punta de un bolígrafo 3 Cuando encienda la balanza después de presionar el botón si ve que no aparece nada en la pantalla asegúrese y compruebe que la pila está instalada y bien conectada En caso de que ya esté instalada ésta puede estar baja sustitúyala por una nueva 4 No utilice disolventes químicos o abrasivos para ...

Page 5: ...ales on a flat solid surface making sure they are firmly positioned Then place the bowl on the platform 2 6 FUNCTIONING 3 TECHNICAL CHARACTERISTICS a Timer alarm b Tare function active c Negative tare value d Zero weight tare inactive e Weight displayed in kg f Weight displayed in lb g Weight displayed in gr h Temperature displayed in ºC 4 ICON DISPLAY FIG 2 1 Press on the button to connect the sc...

Page 6: ...minute You can also switch them off manually by pressing the button weight of the additional article will appear on the display 4 If you remove an article from the bowl a negative value will appear This represents the weight of the article you have removed Press the button again each time you remove an article to set the reading to 0 again NOTE When you activate the scales for the first time if no...

Page 7: ...al temperature on the display 11 TEMPERATURE SENSOR AND INDICATOR h 12 MAINTENANCE AND CLEANING 1 These scales are a precision instrument Make sure they receive no knocks Do not store the scales with a weight on them for long periods 2 Always press the buttons gently Do not use any sharp objects such as ballpoint pens to press them down 3 If nothing appears on the screen when you switch on the sca...

Page 8: ... surface solide et horizontale et vérifier qu elle soit fermement installée Déposer ensuite le bol sur la plate forme 2 6 FONCTIONNEMENT 3 CARACTÉRISTIQUE TECHNIQUES a Minuteur alarme b Fonction tare active c Valeur négative tare d Poids zéro tare inactive e Visualisation poids en Kg f Visualisation poids en Livres g Visualisation poids en g h Visualisation température en ºC 4 VISUALISATION DES IC...

Page 9: ...éposées dans les containeurs spécialement destinés à leur collecte 9 UTILISATION DE LA TOUCHE TARE 4 10 MINUTEUR ALARME 7 PRÉCAUTION NE PAS SURCHARGER L APPAREIL Si vous dépassez la capacité de charge maximale de 1 vous risquez d endommager la balance et l écran affichera l indication suivante 6 Attendre l affichage du zéro avant de procéder à la pesée Si l écran n affiche pas zéro appuyer sur la ...

Page 10: ...omatiquement chaque fois que la balance est allumée Il détecte la température ambiante et indique la température réelle 11 CAPTEUR ET INDICATION DE TEMPÉRATURE h 12 MAINTENANCE ET ENTRETIEN 13 INFORMATION POUR LA CORRECTE GESTION DES RÉSIDUS D APPAREILS ÉLECTRIQUES ET ÉLECTRONIQUES A la fin de la vie utile de l appareil ce dernier ne doit pas être éliminé mélangé aux ordures ménagères brutes Il pe...

Page 11: ...feste und wagerechte Oberfläche und versichern Sie sich dass die Waage gut steht Stellen Sie dann die Schale auf den Sockel 2 6 FUNKTIONSWEISE 1 Betätigen Sie den Knopf um die Waage einzuschalten 2 Das Display schaltet ein und zeigt alle Ikonen an ABB 2 3 Betätigen Sie den Knopf kg lb um die gewünschte Maßeinheit lb oder kg einzustellen Anmerkun Beim Einschalten der Waage erscheint die bei der let...

Page 12: ...iegeguts 4 Wenn Sie das hinzugegebene Wiegegut wieder aus der Schale entnehmen erscheint auf dem Display ein Negativwert Dieser entspricht dem Gewicht des Wiegeguts das zuletzt entnommen wurde Mit dem Knopf können Sie die Waage erneut auf Null stellen jedes Mal nachdem Sie Wiegegut entnommen haben HINWEIS Erscheint beim ersten Einschalten der Waage keine Anzeige auf dem Display oder das Display st...

Page 13: ...eten gebracht werden Die getrennte Entsorgung eines Haushaltsgerätes vermeidet mögliche negative Auswirkungen auf die Umwelt und die Gesundheit die durch eine nicht vorschriftsmäßige Entsorgung bedingt sind Zudem ermöglicht sie die Wiederverwertung der Bestandteile des Gerätes was wiederum eine bedeutende Einsparung an Energie und Ressourcen mit sich bringt Zum Unterstreichen der Verpflichtung zur...

Reviews: