51
OPERATION
Limit the operating time
In order to increase efficiency, the induction hob is fitted with operating time limiter for each of
the cooking zones.
The maximum operating time is determined individually
depending on the heat setting when cooking. If you only
use one heat setting for an extended period of time, the
maximum cooking time is given in the table:
After reaching the maximum cooking time, the induction
zone deactivates automatically, and the display shows
residual heat symbol. The maximum working time
applies to a single cooking zone.
Automatic warm-up function
This function initially sets cooking zone heat setting to
9. Activate the function:
To activate the function:
• Place the cookware on the desired cooking zone.
• When cookware is automatically detected select
the heat setting 1-8
• Touch the sensor again.
The display will alternately show flashing heat setting
and the "A” symbol.
After the warm-up time has elapsed (see table), the
cooking zone will automatically switch back to the pre-
viously selected heat setting and it will be shown on the
display.
If you take the pot off the cooking zone when the warm-
up function is active, and then put back on, warm-up
function will continue until full warm-up time has elapsed.
Cooking heat
setting
Maximum operat-
ing time
8h
1
8h
2
8h
3
5h
4
5h
5
5h
6
1.5h
7
1.5h
8
1.5h
9
1.5h
P
10min
Cooking heat
setting
The duration of
the automatic
warm-up function
(minutes)
1
48s
2
1min, 12s
3
2min, 18s
4
2min, 30s
5
4min, 24s
6
7min, 12s
7
2 min
8
3min, 12s