background image

FOR SWINGING GATES

PLUS

9

Photocells and Safety Edge:

12 13

 24V  OUTPUT (500mm) ( MAX LOAD:

2 PAIRS PHOTOCELLS  and

1 RADIO RECEIVER)

1

2

CONTACT FOR PHOTOCELLS
AND SAFETY EDGE

PHOTOCELLS 2

Keyswitch:

3

4

5

6

STOP

COMMON

OPEN

CLOSE

Radio Contact:

- Open/Close (Standard)
- Any new pulse reverses gate travel
- Step by Step

2

5

ON: Step by Step. Stop in between by
 remote 

control

OFF: Standard Operating Mode as pre-set

ON: No gate travel reversing

on Opening

OFF:Any new pulse reverses gate travel

DIP-SWITCH 2 and 5 (NEVER set both of them to ON at the same time):

COMMON

RADIO CONTACT

8

7

Electric lock:

9 10

 12VAC OUTPUT TO POWER

AN ELECTRIC LOCK

24V 3W Light for Gate Status Indication:

Light

 On

 = Gate Open

Light

 Off

 = Gate Closed

Flashing 

0,5s (fast)

= Gate Closing

Flashing 

1s (standard)

= Gate opening

Flashing 

2s (slow)

= Gate Stopped

8

11

1

DIP-SWITCH 1:

OFF: Photocells do not stop gates on Opening, reverse

gate travel on Closing in case of an obstacle

ON: Photocells stop gates on Opening and reverse gate

travel on Closing once obstacle has been removed

Push Button Switch Pulin3:

26

27

28

3

COMMON

These LEDs indicate when
Open - stop - Close
commands are given

-

+

T4 

ABOVE MINIMUM TO

STRAIGHT CENTRE POSITION.
THE ELECTRIC LOCK IS
EXCITED FOR 4 SECONDS

By setting  T4 Trimmer (Ext.Trimmer) from
above minimum position to straight
centre position, the electric lock is
excited for 4 seconds.
M1 motor is abled to take an electric
lock.

Drwg. No.

4192

6

GB

®

LOW VOLTAGE ELECTRICAL CONNECTIONS

Reviews: