fadini Coral 1080 Fitting Instructions Manual Download Page 8

8

PIC. 10

Drwg. No.

4333

T

S

R

PULIN 3

26

27
28

3

DIP-SWITCH

ON

OFF

1

4 5 6 7 8

2 3

L2

L3

L4

L5

L6

L7

L8

L9

1

7

4

10 11 12 13

19

20

2

8

5

3

9

6

STOP

COMMON

OPEN

CLOSE

230V 25W max

FLASHING LAMP

230/400V

L1

L10

F4=630mA

Transformer

protection

F6=630mA

24V protection

RADIO
PLUG-IN
CARD CONNECTOR

TRANSFORMER

MOTOR RUN TIME
from 5 to 128s

DWELL TIME
from 5 to 128s

PEDESTRIAN
OPENING TIME
from 3 to 30s

-

+

-

+

-

+

-

+

EXT TIME (electric lock and
courtesy light) from 2 to 255s

T4

T3

T2

T1

PHOTOCELLS

SAFETY EDGE

RADIO

LIMIT SWITCH CLOSE

LIMIT SWITCH OPEN

COMMON LIMIT SWITCH

18

16

17

COMMON

M

MOTOR

U

W

V

21

22

NEUTRAL

S

LIVE

23

22

ELECTRIC LOCK OR

12V AC RELA

Y FOR

230V COUR

TESY LIGHT

RS RS

CAPACITOR

230V 50Hz

SINGLE-PHASE

VOLTAGE SUPPLY

400V 50Hz

THREE-PHASE

VOLTAGE SUPPLY

NEUTRAL

LIVE

24V OUTPUT max. load:

2 pairs photocells

1 radio receiver

F1=8A mains

F2=8A mains

F3=8A mains

F5=1A flashing lamp

protection

Voltage cut off switch

and cover locking knob

ELPRO 10 PLUS CEI

INDICA

TION LAMP

24V max. 3W

LIVE

LIVE

In case of failure of the panel:

- Check voltage supply. It must be 230V or 400V 50Hz
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the
  control panel to the electric motor

The electronic control panel Elpro 10 Plus CEI, new generation, is designed to operate sliding gates. Power supply is 230/400V
single-phase and three-phase. Built in full compliance with BT 93/68/CE Low/High Voltage and EMC 93/68/CE Electro-Magnetic
Compatibility Regulations. Fitting operations are recommended by a qualified technician in conformity to the existing safety
standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to
change or update the control panel any time.

PLEASE NOTE:

- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5 mm

2

 section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50 m.

  Use 1 mm

2

 section wires for limit switches, photocells, push-buttons/key-switch and accessories.

- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.

DIP-SWITCH

1

4 5 6 7 8

2

ON

OFF

3

Dip-Switch:

1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function

Led Status Indication:

L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button

L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
L10= It stays on for a time equal to the time set on T4

L7= Gate Status; it flashes on gate opening

ELPRO 10 plus 1.4

MICROPROCESSOR

Summary of Contents for Coral 1080

Page 1: ...FITTING INSTRUCTIONS GB...

Page 2: ...ion soon after fixing the location enclosure fit the mechanism into it carry out the electrical connections and the system is ready to work Once a pulse is given either by keyswitch or remote control...

Page 3: ...he components ie the inner motor pump and actuator assembly can be easily lifted out using mechanical aid Pic 2 IMPORTANT make sure the electric cables are not damaged or accidentally removed from ter...

Page 4: ...side of the enclosure to the tube centre line Pic 13 and 14 Front view View of the side where a hole is provided for a cable duct to be fitted A hole will be required in the road surface where Coral 1...

Page 5: ...ch cables should be pulled through the duct a rope pull through previously inserted and the inner assembly gently lowered onto the location enclosure IMPORTANT Pull the electric motor and limit switch...

Page 6: ...ted as indicated in the diagram a 20 F capacitor in parallel with the two live terminals Control unit ELPRO 10 PLUS CEI Power supply 230V 50Hz Electric Motor Cable 20 F capacitor fitted inside Elpro 1...

Page 7: ...square section of 1 5 mm2 for a distance not superior to 50 m For longer distances use 2 mm2 wires To connect the photo cells key or button operated switches and other accessories 1 mm2 wires can be u...

Page 8: ...ing operations are recommended by a qualified technician in conformity to the existing safety standards The manufacturing company declines any responsability for incorrect handling and application als...

Page 9: ...utomatic Mode 400V 50Hz THREE PHASE Holdonswitched Deadman control Pedestrian Opening Trimmer T3 OPERATING MODES from 3 to 30s It can be activated by any pulse eg by remote control superior to 2s 3 DI...

Page 10: ...e 2A Control Unit ELPRO 10 PLUS CEI GREEN RED Mains Supply 230V 50Hz IMPORTANT For security reasons failure of the red light prevents even the green light from illuminating Interface for the electrica...

Page 11: ...to lower the bollard 4 and eventually re establish normal operation by rotating the spanner clockwise to the original position 5 To re establish normal operation first turn the spanner clockwise to l...

Page 12: ...stem which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of improvement The CE mark certif...

Reviews: