8
PIC. 10
Drwg. No.
4333
T
S
R
PULIN 3
26
27
28
3
DIP-SWITCH
ON
OFF
1
4 5 6 7 8
2 3
L2
L3
L4
L5
L6
L7
L8
L9
1
7
4
10 11 12 13
19
20
2
8
5
3
9
6
STOP
COMMON
OPEN
CLOSE
230V 25W max
FLASHING LAMP
230/400V
L1
L10
F4=630mA
Transformer
protection
F6=630mA
24V protection
RADIO
PLUG-IN
CARD CONNECTOR
TRANSFORMER
MOTOR RUN TIME
from 5 to 128s
DWELL TIME
from 5 to 128s
PEDESTRIAN
OPENING TIME
from 3 to 30s
-
+
-
+
-
+
-
+
EXT TIME (electric lock and
courtesy light) from 2 to 255s
T4
T3
T2
T1
PHOTOCELLS
SAFETY EDGE
RADIO
LIMIT SWITCH CLOSE
LIMIT SWITCH OPEN
COMMON LIMIT SWITCH
18
16
17
COMMON
M
MOTOR
U
W
V
21
22
NEUTRAL
S
LIVE
23
22
ELECTRIC LOCK OR
12V AC RELA
Y FOR
230V COUR
TESY LIGHT
RS RS
CAPACITOR
230V 50Hz
SINGLE-PHASE
VOLTAGE SUPPLY
400V 50Hz
THREE-PHASE
VOLTAGE SUPPLY
NEUTRAL
LIVE
24V OUTPUT max. load:
2 pairs photocells
1 radio receiver
F1=8A mains
F2=8A mains
F3=8A mains
F5=1A flashing lamp
protection
Voltage cut off switch
and cover locking knob
ELPRO 10 PLUS CEI
INDICA
TION LAMP
24V max. 3W
LIVE
LIVE
In case of failure of the panel:
- Check voltage supply. It must be 230V or 400V 50Hz
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the
control panel to the electric motor
The electronic control panel Elpro 10 Plus CEI, new generation, is designed to operate sliding gates. Power supply is 230/400V
single-phase and three-phase. Built in full compliance with BT 93/68/CE Low/High Voltage and EMC 93/68/CE Electro-Magnetic
Compatibility Regulations. Fitting operations are recommended by a qualified technician in conformity to the existing safety
standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to
change or update the control panel any time.
PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5 mm
2
section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50 m.
Use 1 mm
2
section wires for limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
DIP-SWITCH
1
4 5 6 7 8
2
ON
OFF
3
Dip-Switch:
1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function
Led Status Indication:
L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
L10= It stays on for a time equal to the time set on T4
L7= Gate Status; it flashes on gate opening
ELPRO 10 plus 1.4
MICROPROCESSOR
Summary of Contents for Coral 1080