www.factorelectronics.com
Rear Panel Operations and Connections
REMOTE MUTE
– The MUTE contacts can be used to instantly mute
background music sources for immediate paging or emergency
situations. Simply short the MUTE contacts with a switch or external
contact closure from the optional V-RMC and all inputs will mute with
the exception of the PRIORITY inputs. PRIORITY inputs will function as
normal provided the PRIORITY function is ON. NOTE: When using the
V-RVC for a remote music input it is recommended to short the mute
contacts. The V-RVC will override other music sources that may be
connected to the amplifier.
BRIDGING INPUT/OUTPUT
– Many installations require flexibility
where multiple amplifiers need to be combined for large room
activities and then separated for smaller multiple room activities. This
is referred to as room combining. Factor Electronics amplifiers offer
this feature with simple easy to use bridging terminals. These
terminals provide a way to send and receive balanced line level audio
from the internal mixer of the preamplifier. The bridging terminals
balanced signal can be sent long distances without introducing noise or
interference using 22 AWG or 24 AWG shielded two conductor stranded
copper wire.
Connect the br / -- / G terminals of one Factor Electronics
amplifier to the same terminals on another Factor Electronics amplifier.
The amplifiers will operate independently until the SEL contacts are
shorted.