background image

 

 

 

-15- 

Maintenance-free Lead Acid battery 

Guidelines for maintenance-free Batteries: 
1. Battery should operate at temperatures between 15°C ~ 50°C. To ensure a longer life span, it 

should be kept between 5°C ~ 35°C. For optimum result, 20°C ~ 25°C will be ideal. When 
temperature falls 15 degrees below zero, battery will undergo some changes in its chemical 
contents and therefore cannot be recharged. Operating the battery at higher temperature will result 
in higher capacity but shorter lifespan, whereas lower temperatures operation has a longer lifespan 
but less capacity. 

2. If the battery is not recharged 72 hrs after it is completely used, it will be permanently damaged.  
3. When the battery is being charged, the internal gases will be electrolyzed into water at the 

negative charge, maintaining the battery’s storage abilities with no water added. However, erosion 
at the charged ends of the battery will cause poor performance.  

4. 

The battery’s cycle lifespan (no. of charge and discharge cycle) is determined by the degree at 
which power is dissipated, especially the degree of discharged each time it is used and the 
recovery charging method. For normal use, the battery can be used for longer hours when less 
power is dissipated each time and vice versa. At 25°C, maintenance-free batteries could be 
charged 150 ~ 200 times at 100% discharge each time.  

5. Decrease in capacity, internal short circuit, deformation in appearance, erosion of charged ends 

and decrease in open circuit voltage are symbols indicating battery is approaching the end of its 
life cycle. 

6. When two batteries are used in parallel connection, the resistance of the cables should be kept 

equal.  

  
Properties of the Lead Acid Battery: 
1. Has no memory effect. Can be charged anytime, even when the recharge indication light is off. 
2. Performance and efficiency are affected by changes in the environment, especially temperature 

and humidity. (Best operated between 20°C ~ 25°C) 

3. Battery discharge naturally according to a certain pattern even not in use. For best performance 

and a prolonged lifespan, it should be recharged every month even when not in use. 

4. Under normal circumstances, battery could last for about a year. 
5. 

When the battery’s life expires, possible indicators include internal short-circuit, decrease in 
capacity, deformation in appearance, erosion of charged ends and decrease in operating voltage.  

  
User’s Precautions: 
1. For first-time use, charge the battery for 10 hrs until it is fully charged. 
2. To maintain performance and lifespan, if product has not been used for 3 months after the initial 

shipment, please fully charge the battery.  

3. 

Before each use, it’s advisable to charge the battery to its full capacity. 

4. The average lifespan of the battery is one year. The user is advised to change the battery after 

one year of use.  

5. 

The current consumption is in direct ratio with load current. The more current consumption, the 
less the operation time.

 

 
 
 
 
 
 
 

12I2226 

Summary of Contents for PRESENTER ONE

Page 1: ...Modulized Wireless Portable Amplifier System ISO 9001 2008 GREEN PRODUCT Operation manual...

Page 2: ...on with no module installed Optional accessories 1 Weather proof dust cover 2 Tripod stand 3 Companion powered speaker PRESENTER TWO 4 Wired microphone Remark Manufacturer reserves the rights to chang...

Page 3: ...D power volume control 4 Tone voulme control BASS 5 Tone voulme control TREBLE 6 Master volume control 7 Mic input Balanced Unbalanced 8 Line input output R L 9 Voice priority 10 Slave output 11 Batte...

Page 4: ...smitter 1 Audio link input 2 Audio link output 3 Volume control 4 Speaker out switched 5 Speaker out unswitched 6 24 32V DC input 7 Fuse 8 Power status indicator RED 9 Power status indicator GREEN 10...

Page 5: ...e sure that master volume control is set to minimum level before turning the unit on especially working on a wireless version Set the Master volume control to the mid position Rotate the volume contro...

Page 6: ...ster and the other PRESENTER ONE as slave To do that just put the MASTER SLAVE selector switch of the second PRESENTER ONE to SLAVE mode For the MASTER unit Audio Link IN jack should NOT be connected...

Page 7: ...and largely extends the number limit of SLAVEs Application For crowds of 1000 to 2000 e g speeches or forums Configuration One Master several SLAVEs with receiver module built in Application For crow...

Page 8: ...received CHANNEL scanning It is the automatic scan function key To perform the scan function the transmitter must be switched off Once the key is being pressed the unit will do an auto scan and the ne...

Page 9: ...o sensitivity Clockwise to increase its sensitivity level and anticlockwise to reduce 6 Output power setting LOW left for Low output power and HI right for high output power Low output power will redu...

Page 10: ...if it is in the last track In program entry mode Change to the next track file for program select In play mode pause mode program play mode random play mode Single pressed skip the playing track file...

Page 11: ...OM REPEAT PLAY ALL V EJECT When this key is pushed door is moved out V V PROG Set to programming mode When programming mode stop key is pushed then program is all cleared V MUTE When this key is pushe...

Page 12: ...wn to have leakage problem of conductive and corrosive liquid So please remove the batteries if they are not to be used for a long period Other settings 1 Channel setting Use UP or DOWN button to go t...

Page 13: ...vity Level Use UP or DOWN button to go to the SENS SET page Press UP or DOWN button to increase or decrease the Sensitivity Level of the microphone The MAX level is 4 and the MIN level is 1 When a des...

Page 14: ...es according to the correct polarity after opening the compartment Many batteries are known to have leakage problem of conductive and corrosive liquid So please remove the batteries if they are not to...

Page 15: ...ne battery position When the desired battery has been selected it will be automatically saved and stored in the memory Remark NiMH battery must be selected when rechargeable battery is being used Neve...

Page 16: ...ity internal short circuit deformation in appearance erosion of charged ends and decrease in open circuit voltage are symbols indicating battery is approaching the end of its life cycle 6 When two bat...