Installation:
Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
The carrying construction must be able to support 10 times the weight of the device for 1 hour without deforming.
Never stand directly below the device when it
’
s being mounted, removed or serviced.
Have a qualified technician check the device once a year and once before you bring it into service.
Install the device in a location with few passers-by that is inaccessible to unauthorized people.
Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
Make sure there is no flammable material with a 50cm radius of the device.
Connect the device to the mains with the power plug.
The installation has to be approved by an expert before the device is taken into service.
Specifications:
Power supply
AC220V-230V / 50Hz
Power
1500W
Reheat time
4 Min (approx.)
Fog output (approx.)
20,000 Cu/Ft. (283m³) / min
Tank capacity
2.5L
Remote control frequency
433 MHz
Dimensions
42 x 33 x 26 cm
Setting up and operation
The FS-UP-1500-DMX requires fog fluid to produce the effect.
It is recommended to use one of the ranges of Triton-Blue fog fluids for best results.
1. Unscrew the top cap of the tank and remove to fill with the selected fog fluid.
2. Replace the cap and close securely, ensuring the pipe is fed down to the bottom of the bottle so a consistent flow of
fluid is supplied to the machine.
3. Connect the IEC mains plug.
4. Check the fog fluid level indicator at the rear and fill if necessary.
5. Switch the mains power on.
6. Heat up time is approximately 3-6 minutes. Please ensure that the remote button. Is not pressed during the heat up
time.
7. Switch off when not in use.
8. Unplug from mains if not in use for long periods.
Warning:
Hot components. Switch off and allow cooling before touching the unit.
Troubleshooting
No light on mains switch
Check mains voltage is correct and socket is switched on
Check IEC lead is OK and connected properly
Check mains fuse and fuse in plug top
If fuse blowing repeatedly, refer to qualified service personnel
Wired remote light not lighting
Check remote is connected properly
If light is permanently off, refer to qualified service personnel
Remote light is on but no
fog output
Check fog fluid level (Fluid Low indicator)
If fluid is OK and pump working, the lines may be blocked
Check that nozzle is not blocked or obstructed
If blocked, clean with fog machine cleaner & distilled water