Each pack of tubes has its own instruction leaflet but the following notes should help you take
readings after the tests have been completed.
Each tube has an expiry date which is located on the back of its storage box.
Oil (67 28371)
REQUIREMENT
- THE AIR SHOULD HAVE A MAXIMUM OIL CONTENT OF 0.5 MG/M³
AND SHOULD BE WITHOUT SIGNIFICANT ODOUR OR TASTE.
Ensure the oil tube is kept vertical throughout this process.
Satisfactory test: - The white crystals will turn translucent and show at worst a slight discoloration.
Failed test:
- (Mineral oil) - The white crystals will show a light brown or darker
discoloration.
- (Synthetic oil) - The white crystals will show a yellow discoloration
[Note: best
seen by comparing with an unused tube
].