CE DECLARATION OF CONFORMITY
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - 91 420 MORANGIS - FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE PRODUCT
V.D600QR – FACOM 6 MM PNEUMATIC DRILL
- IS IN CONFORMITY WITH THE «MACHINERY»
DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN
STANDARD
EN
ISO 11148-3: 2012
The undersigned is responsible for compilation of the technical fi le and makes this declaration on behalf of Facom.
20.03.2016
Director Engineering
1/4 NPT
Ø 10 mm
3/8 "
* k = measurement uncertainty in dB * k = measurement uncertainty in m/s²
Model
Rated speed
Air consumption
Working
pressure
Weight
Dimensions
rpm
l/min
bar
kg
mm
V.D600QR
2600
113
6,2
0,57
144x39x136
GETTING STARTED WITH THE MACHINE
EMERGENCY
GATE VALVE
LUBRICATION
Always use of an air line lubricator with these tools. We recommended the
following Filter-Lubricator-Regulator Unit:
FACOM N.580
.
Every eight hours’ operation, if a lubricator is not used on the compressed
air network, inject 1/2 to 1cm3 through the machine’s inlet connection.
Markus Rompel
1
2
3
4
➠
➠
➠
➠
Model
Chuck capacity Motor power
rating
Noise level
Vibrations level
m/s
2
Pressure dB(A)
Power dB(A)
Pressure dB(C)
mm
kW
k*
k*
k*
k**
V.D600QR
6
0,3
84
3
95
3
130
3
0,4
0,24
NU-V.D600QR_0616.indd 8
29/06/2016 10:42:15
Summary of Contents for V.D600QR
Page 48: ...BG FACOM 6 2 bar 620 kPa 10 mm 6 2 bar 6 2 bar NU V D600QR_0616 indd 48 29 06 2016 10 42 48...
Page 49: ...FACOM FACOM FACOM FACOM FACOM 1 2 1 3 NU V D600QR_0616 indd 49 29 06 2016 10 42 50...
Page 54: ...RU FACOM 6 2 620 10 6 2 6 2 NU V D600QR_0616 indd 54 29 06 2016 10 42 56...
Page 55: ...FACOM FACOM FACOM FACOM FACOM 1 2 1c 3 NU V D600QR_0616 indd 55 29 06 2016 10 42 57...
Page 61: ...NOTA NU V D600QR_0616 indd 61 29 06 2016 10 43 09...