Facnor - Installation manual rev 2012 – LS+/LX+/RX+ reefing and furling systems
2.2 TUBE CONTENT
1.
one telescopic section (1M40)
2.
external twin-groove sections
3.
connectors
For OEM furling systems (delivered originally to the shipyard) the top section may be shorter
than 2 meters. For those systems, the top section is cut at a specific length.
Example: if you order an FD190
12M40
, according to the chart below you will receive
five 2-
meter sections, one half-length section, the telescopic section and five connectors
.
Chart No.3
Forestay
max. length
No. of 2m
sections
No. of 1m
sections
No. of
connectors
Telescopic
section
7M30 3
0
2
1
8M40 3
1
3
1
10M40 4
1
4 1
12M40 5
1
5 1
14M50 6
1
6 1
16M50 7
1
7 1
18M50 8
1
8 1
20M50 9
1
9 1
22M50 10
1
10 1
2.3 DETERMINING WHICH SECTION LENGTH SHOULD BE USED
The example given is of a LS165 12M40, standard (i.e. not delivered to a shipyard), for a
forestay measuring between 10.4 and 12.4 metres. According to the table above, you will
receive: 5 two-metre external sections and 1 one-metre external section.
EXAMPLE No1 :
your forestay measures between
10.40 and 11.40 metres (fig. A),
you
do not need the 1-metre section.
EXAMPLE No2:
your forestay measures between
11.40 and 12.40 metres,
you do need
the 1-metre section
(fig. B)
; the latter fits above the last section.
In both examples, the exact length will be reached with the telescopic section (fig. C).
20