Fabit E Series User Manual Download Page 10

SHENZHEN FABIT M&E EQUIPMENT CO. LTD.

 

which needs to be pumped, and the oil pumping equipment needed.   

Check the oil outlet size and structure, select the appropriate needle oil pumping and 

 

required others devices 

 

b)  Insert the oil pumping needle inside the pump, and open the pumping valve/ handle 

ball/opening 

The oil will be pumped into the transparent cup, after the completion of pumping, close 

the pipe valve. 

 

7.  Oil Connector - Operating method 

1

The device should be placed in an appropriate position, adjust the height of the lifting rod to 
the correct one, the rotation of the eccentric pan beneath the oil discharge outlet, unscrew the 
nut at the bottom of the tank, began to fill the oil.   

2

Open the lift rod connected to the lower ball valve, storage the oil in a proper tank.   

3

Wait until drainer completion of the oil, then close the valve (under the ball valve), and  

 

remove the equipment.   

 

8.  Oil Discharged- Operating method

 

 

1)  Collect oil from the cup to the tank 

 

 

Open the cup ball button, the transparent cup content will be discharged into the tank

 

 

2)  Collect oil from the tank to the cup/bucket/container, etc 

 

a)

Natural drainage

Close the tank (elbow valve), open full the ball valve, the tank is 

connected with an external air, oil discharge outlet pipe will be linked to the waste 
oil collection container, open the tank, pressure in the atmosphere will be 
discharged into the oil collecting container (oil drain pipe the outlet must be below 
the liquid in the tank)   

b)

Pressurized oil discharge

Shut down the pipeline ball valve ball valve and lift rod 

is connected below the measuring cup, the discharge pipe hanging in the waste oil 
collection container, open the bottom of the oil tank in the exhaust valve, inlet 
nozzle access 1bar compressed air, the compressed air enters the tank; under the 
action of the compressed air storage tank, oil will continue to be drained to the 
waste oil collecting container. (the pressure inside the tank, more than 1.5bar, the 
safety valve automatically opens, this time, cut off the gas source).   

 
When discharging, please hold the bent hook or fixed line bent hook.   

9.  Safety Inspections 

 

1

Pre-work Inspection 

     Every day before work, close all valves, vacuum cups and the tank, and then carefully 
 

observe the vacuum table pointer changes, make sure each part is assembled and no leaked. 

 

Please contacted the vendor to solve problems, to avoid property damage or accidents.   

ADD: Huli Industrial Zone, NO.4 Xinwei Industrial Estate, Gongming Office, Guangming District, Shenzhen , China. 
TEL: 86 0755 61136563    FAX: 86 0755 27125016    E-mail: 

[email protected]

     WEBSITE: http: //www.fabit.cn 

10 

Summary of Contents for E Series

Page 1: ...seller immediately to get another copy or replace the labels Warning In the installation instructions the following definitions are included in the danger caution and attention They mean danger warnin...

Page 2: ...ed air as power source especially suitable for produce accidents such as explosion The good sealing and reliable operation are required to avoid accidents The oil pump has advantages such as convenien...

Page 3: ...0 43 41 45 44 49 48 47 28 29 30 32 31 42 14 25 39 27 4 38 48 44 15 19 20 21 12 13 46 17 18 ADD Huli Industrial Zone NO 4 Xinwei Industrial Estate Gongming Office Guangming District Shenzhen China TEL...

Page 4: ...bing 25 Muffler 43 Tool box 8 Cover 26 Pumping pipe 44 Level pipe elbow 9 Sealing ring 27 Oil pump 45 Liquid level pipe 10 Gland nut 28 Hook 46 M12 Half nut 11 Cup ball valve 29 Oil pump pipe ball val...

Page 5: ...the guide sleeve adjust to the appropriate height the fixed lock ring Figure C connecting the lifting rod assembly and a drip pan as shown in figure C the pan is inserted into the lifting rod assembl...

Page 6: ...sembled without the oil suction pipe and generator The Cover Central tube ventilation and oil Cup body Top cover nut 6 Pumping needle 8 Pumping needle Ball valve ADD Huli Industrial Zone NO 4 Xinwei I...

Page 7: ...E 43075E 43090E 42080E 42081E 42095E 42096E 44080E 44081E 44095E 44096E 44090E 44105E 44110E 44120 E ADD Huli Industrial Zone NO 4 Xinwei Industrial Estate Gongming Office Guangming District Shenzhen...

Page 8: ...tions If the installation instructions are missing or defaced warning label peeling please contact the seller 2 Danger and warning Forbidden Disassembly Due to the use of vacuum pressure products vari...

Page 9: ...umped into the transparent cup or tank Then outside the air pressure in the tank has to waste oil into a container tank etc 1 Vacuum pumping a Transparent vacuum cup Close the following pumping hose i...

Page 10: ...nected with an external air oil discharge outlet pipe will be linked to the waste oil collection container open the tank pressure in the atmosphere will be discharged into the oil collecting container...

Page 11: ...you are still doubting on the procedure please contact the vendor Fault Reason Processing Method Vacuum degree is not enough Lack of air pressure Adjust the flow pressure to achieve the specified pre...

Page 12: ...please contact the vendor or manufacturer 12 Product Warranty 1 Warranty provisions During the warranty period under full compliance with this operating instructions and procedures and the ones on the...

Page 13: ...Reparation after the warranty period Please discuss with the vendors If the repair can still maintain the product function to meet user requirements Provide paid repair For details of the after sales...

Page 14: ...se Y M D Customer Information Company Contact Person Address Tel Fault status Date Status Cause Analysis Solution Date Status Cause Analysis Solution ADD Huli Industrial Zone NO 4 Xinwei Industrial Es...

Reviews: