- 4 -
http://www.fabit.cn
INSTRUCTION MANUAL
WASTE OIL EVACUATION SYSTEM
43075H
Page 1: ...e larger than before Attention Please according to the type of your car Machinery Equipment to choose the right Diameter of Probe tube when you use the machine to drain oil directly from the tank READ THIS INFORMATION CAREFULLY BEFORE USE Please retain this instruction manual for future reference Your safety is important to us Please read and follow all instructions listed below Some of these inst...
Page 2: ...OF SUCTIONING OIL Operational principle With the air compression principle using the special designed vacuum generator vacummize both the measuring cup and oil tank at the same time it will create the vacuum pressure difference to draining the waste oil into the clean measuring cup and oil tank 1 Vacuumize oil tank measuring cup Before evacuating the cup please close all ball valves Quickly connec...
Page 3: ...ore working Before working please turn off all the ball valves and vacuumize the oil tank and measuring cup Then carefully check the indicator s change of the vacuum meter to see whether any part of the machine is with air leak or not If any leakage please contact the sales agent to avoid any property damage or personal injure accident Attention During vacuumizing check the indicator s change of t...
Page 4: ... 4 http www fabit cn INSTRUCTION MANUAL WASTE OIL EVACUATION SYSTEM 43075H ...
Page 5: ...the one of cup inlet Vacuum generator damage Contact the seller to replace Slow draining Insufficient vacuum Do not use before vacuum achieve the specified value The O ring of draining needle tube damaged Contact the seller to replace Air leak Contact with the vendor to determine the location of the leak under the guidance Tank Capacity 70L Air pressure for vacuum 6 8bar 87 116psi Max draining pre...