![Fabit 42080E User Manual Download Page 11](http://html.mh-extra.com/html/fabit/42080e/42080e_user-manual_536502011.webp)
SHENZHEN FABIT M&E EQUIPMENT CO. LTD.
Note
:
on vacuum process, carefully observe the vacuum table pointer, when the pointer has
reached
the red scale area, cut off the compressed air, complete the vacuum
pumping
operation.
2
)
Periodic Inspection
1
)
Leak check
2
)
Oil leak check
3) Make sure that the hose and fittings are not damaged, deformed, worn or stained.
Note:
On a regular basis, it is recommended that professional personnel manage the product
and
do the inspections. For details, please consult the vendors.
3
)
Complete Inspection
After the end of the operation, the products must be free of adhered materials or stains
(water, debris, oil, etc.) wipe clean. If there is abnormal signal, immediately contact the seller.
4) Other Considerations
:
10. Troubleshooting
Please first read the instruction manual carefully and check the following items. If you are still
doubting on the procedure, please contact the vendor.
Fault
Reason
Processing Method
Vacuum degree is
not enough
Lack of air pressure
Adjust the flow pressure to
achieve the specified pressure.
Broken cup
Contact vendor for replacement
Vacuum table damage
Contact vendor for replacement
In addition to the intake valve,
the mouth of the cup is is not
closed
In addition to close the cup
external inlet
,
close all ball
valves
Vacuum generator damage
Contact vendor for replacement
Attention
1. Inspection Notes
1
)
Please, do pre-work and regular inspection, according to the content of this guide.
2
)
Do not use this product without pumping oil not connected.
2
.
Use matters attention
1
)
This product is strictly prohibited for contacting with fire or corrosive liquid
;
2
)
Don NOT go beyond the usual pressure range when used
。
ADD: Huli Industrial Zone, NO.4 Xinwei Industrial Estate, Gongming Office, Guangming District, Shenzhen , China.
TEL: 86 0755 61136563 FAX: 86 0755 27125016 E-mail:
11