Faber Torch framed Installation Manual Download Page 10

 
 

>

 

>

 

>

 > 6 

UK

IRL 

6

 

 Servicing 

To ensure safe and efficient operation of the appliance, it is necessary to carry out routine 

servicing at regular intervals. It is recommended, that the fire is inspected/serviced by a 

competent person at least once a year. 

Important: turn off the gas supply before commencing any servicing. Always test for gas 

soundness after refitting the appliance. 

The appliance and flue connection have to be checked for gas and smoke soundness after 

installation. 

6.1

 

Routine servicing 

Clean (if necessary): 

 

the pilot system 

 

the burner 

 

the combustion chamber 

 

the glass 

 

Do the functional tests 

 

Check the flue system and terminal on damage and soundness (visual inspection) 

6.1.1

 

Cleaning the glass 

Depending on the intensity of use, you can get a deposit on the glass. Normally this can be 

removed with an ordinary dry towel. If necessary special ceramic glass cleaner (ceramic 

cook-top cleaner) can be used. To clean the glass: 

 

Remove the Front Frame 

 

Remove the glass in it’s frame 

 

Clean the glass. Handle the glass with clean hands, wear gloves if possible 

 

To fit the glass, proceed in reverse order. Make sure that: 

o

 

the glass sealing rope is in good condition and makes an effective seal 

o

 

Important: be sure that there are no fingerprints on the glass. They are 

burned in the glass when not removed. 

6.1.2

 

Cleaning the combustion chamber and burner 

You can clean the combustion chamber with a vacuum cleaner and soft brush. 

If the burner is visibly damaged, this can affect the performance of the appliance. If so, 

then replace the relevant parts. 

Summary of Contents for Torch framed

Page 1: ...Torch framed Installation Guide IRL UK 40010567 0602 ...

Page 2: ...1 1 2 3 4 ...

Page 3: ... 2 5 6 7 ...

Page 4: ...ns of the appliance 3 4 Installation instructions 4 4 1 Gas connection 4 4 2 Installing the appliance 4 5 Commissioning Functional checks 5 5 1 Pilot ignition check 5 5 2 Check functional burner and pilot burner 5 6 Servicing 6 6 1 Routine servicing 6 6 2 Combustion test 7 Appendix A Spare parts 8 Apppendix B Technical data 9 ...

Page 5: ...ions with the user This guide covers the following appliances Torch framed Torch framed Propane LPG Special features Special patented Torch flame technology Multi vent appliance for wall connection only Remote Control option available Meets the essential requirements of the European Gas Appliance Directive GAD and carries the CE mark ...

Page 6: ...fety It is the law in the UK that all gas appliances are installed by a competent person in accordance with the Gas Safety Installation and Use Regulations as amended the relevant British Standards for Installation work Building Regulations Codes of Practice and the manufacturers instructions Always use an additional guard if there are elderly infirm or children in the same room of the appliance T...

Page 7: ...ements The rear wall must be of a non combustible material see figure 1 for drilling patern Minimum distance from the back of the appliance to the wall has to be 22mm This gap should be maintained by the mounting brackets which fit flush onto the rear wall The plaster has to be resistant to a high temperature Therefore use plaster materials especially made for this to prevent discolouring min 100 ...

Page 8: ...it Then you can go on installing a fixed or flexible connection This has to be CE certified When installed as described above the burner can always be disassembled for servicing 4 2 Installing the appliance Check if the wall is sufficiently level If necessary improve it Insulate the back wall if necessary with promatect or comparable inflammable material Position the saddle and mark the hole centr...

Page 9: ...Check if the measured pressure is the same as the prescribed pressure Perform this measuring when the appliance burns on full capacity and when only the pilot ignition burns When the pressure is too low check if the gas pipes are made of material with the right diameter When the pressure is too high more than 5 mBar overpressure you can t install the appliance and you should contact your gas compa...

Page 10: ...ection 6 1 1 Cleaning the glass Depending on the intensity of use you can get a deposit on the glass Normally this can be removed with an ordinary dry towel If necessary special ceramic glass cleaner ceramic cook top cleaner can be used To clean the glass Remove the Front Frame Remove the glass in it s frame Clean the glass Handle the glass with clean hands wear gloves if possible To fit the glass...

Page 11: ...BS7967 combustion analysis check should be carried out using an analyser to MantleBS7927 positioned in the outlet The performance of the appliance should be checked 6 2 1 Procedure for performance test Ignite the fire and run at FULL for a minimum of 15 minutes Record the Carbon Dioxide CO2 reading at the outlet most analysers will display this as a percentage Repeat test for Carbon Monoxide CO th...

Page 12: ...ass 04510930 04510930 Burner Natural gas 20861096 Burner Propane 20532935 Remote assembly 20604500 20604500 Gasvalve 37003098 37003098 HT Lead 06017301 06017301 Spark electrode 06006500 06006500 Pilot Burner assembly NG 37001030 37001030 Thermocouple 37002041 37002041 ...

Page 13: ...20 37 Gasrate 15 C 1013 bar m3 h kg h 0 260 0 16 Injector size mm 1 20 0 8 Pilot assembly Type SIT 145 SIT 145 Code Nr 30 Nr 15 Outlet terminal size mm 150 100 150 100 Gas control Mertik GV36 Mertik GV36 Remote control Mertik G30 ZRPS 800 Mertik G30 ZRPS 800 Batteries remote 1x 9V MN1604 6LR61 1x 9V MN1604 6LR61 Batteries receiver 4x 1 5V LR03 Alkaline 2x 1 5V LR03 Alkaline Gas connection 8mm nut ...

Page 14: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 40010567 0602 ...

Reviews: