Faber Titano Instruction Manual Download Page 9

 

 

 

 

 

EN 

1

10 

MAINTENANCE

 

Grease filters 

CLEANING METAL SELF- SUPPORTING GREASE FILTERS 

•  The filters must be cleaned every 2 months of operation, or 

more frequently for particularly heavy usage, and can be 
washed in a dishwasher. 

•  Remove the filters one at a time by pushing them towards the 

back of the group and pulling down at the same time.  

•  Wash the filters, taking care not to bend them. Allow them to 

dry before refitting. 

•  When refitting the filters, make sure that the handle is visible 

on the outside.

 

 

Activated charcoal filter (Recirculation version) 

These filters are not washable and cannot be regenerated, and 
must be replaced approximately every 4 months of operation, or 
more frequently with heavy usage.  

REPLACING THE ACTIVATED CHARCOAL FILTER 

•  Remove the metal grease filters 
•  Remove the saturated activated charcoal filter as shown (

A

). 

•  Fit the new filters (

B

). 

•  Replace the metal grease filters.

 

 

A

B

Lighting unit 

Warning

: This appliance is fitted with a white LED lamp classed as 1M 

according to EN 60825-1: 1994 + A1:2002 + A2:2001 standards; maxi-
mum optical power emitted @439nm: 7µW. Do not look directly at the 
light through optical devices (binoculars, magnifying glasses…). 
 
•  For replacement contact technical support. ("To purchase contact tech-

nical support")

 

 

Summary of Contents for Titano

Page 1: ...INSTRUCTIONS MANUAL EN TITANO...

Page 2: ...lationforthegashobspecifyagreaterdistancespecifiedabove thishas tobetakenintoaccount Regulationsconcerningthedischargeofairhavetobefulfilled USE Theextractorhoodhasbeendesignedexclusivelyfordomesticus...

Page 3: ...Controls Light Suction Unit Filters Lower Duct 7 1 PVC Pipe fitted 8 1 Inclinable grid fitted 9 1 Reduction flange 150 120 mm 10 1 Metal cover Ref Q ty Assembly components 11 2 Wall Plugs 11a 2 SB 12...

Page 4: ...EN 5 5 Dimensions...

Page 5: ...e fitted a Horizontal line 550 mm min above the Hob As shown in the drawing mark a reference point 720 mm above the reference horizontal line and at a distance of 155 mm to the right of the vertical r...

Page 6: ...ing diameter is 150 REAR AIR OUTLET When drilling the air outlet hole in the wall proceed in accor dance with the scheme in the part concerning the wall drilling Use a pair of tongs when breaking the...

Page 7: ...rid 8 on the air outlet Make sure that the position of the grid is correct Make sure that charcoal filters have been placed inside the hood 8 7 ELECTRICAL CONNECTION Connect the hood to the mains thro...

Page 8: ...le to change the operating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 second...

Page 9: ...r Recirculation version These filters are not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently with heavy usage REPLACING THE ACTIVA...

Reviews: