Appendix A: Example calculation
Example calculation 1:
Calculating horizontal extension fig. 2a:
Flue length C + E = 1m + 1m
2
m
Elbows D = 2m
2 m
Total horizontal extension
4 m
Measure or calculate effective height (Hvert)
Flue
length
A
1
m
Roof
mounted
terminal
1
m
Total effective height
2 m
Example calculation 2:
Calculation horizontal extension fig. 2b:
Flue length J + L = 0,5 + 0,5
1 m
Elbows K + M = 2m + 2m
4 m
Terminal
1 m
Total horizontal extension
6 m
Calculation effective height (Hvert)
Flue
length
H
1
m
Looking up in the table in Appendix B shows that this
situation is not allowed
Always check if the calculated situation is allowed (see Apppendix B: Flue restrictor)
Ex.1
Ex .2