TOOLS  NEEDED  FOR  INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1  1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS  SUPPLIED  FOR  INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS  NEEDED  FOR  INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE
• 30" High Backsplash
30" high, mounts to the wall beneath the rangehood
for a coordinated look
part # 620000095 - 30" model
part # 620000097 - 36" model
part # 620000098 - 48" model
• Telescopic Chimney Kit (FIGURE 3)
24" wide, extends to accomodate 8 - 9 foot ceilings
part # 6097336 fits all size hoods
• Full Width Duct Cover (FIGURE 4)
12" high, extends full width of the hood
part # 6097337 - 30" model
part # 6097338 - 36" model
part # 6097339 - 48" model
• Duct Transition Kit
For 48" model only, optional kit transitions two 3 1/
4" x 10" openings to one 10" round opening
part # 6000002
• *Charcoal Filters
* it is highly recommended that professional style cooking
always be vented to the outside; for recirulating
installations, some ductwork is required to exhaust the
unit out of the cabinet. For 48" model, order 2 kits.
part # 6093034

RANGEHOOD  WITH

TELESCOPIC CHIMNEY KIT

CALCULATE  THE  DUCTRUN  LENGTH

   WARNING

!

Due to the weight and size of the rangehood
canopy, two or more people are needed to move
and safely install the rangehood canopy.

Failure to properly lift rangehood could result in
damage to the product or personal injury.

PERSONAL INJURY HAZARD

9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap

Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE  2

3.0 feet
5.0 feet

12.0 feet

0.0 feet

45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap

FIGURE 1

PLAN  THE  INSTALLATION

This rangehood can be vented through the wall or ceiling.  To vent through
a wall, the blower must be turned to vent to the rear.  This rangehood can
be installed with two different chimney options as well as without a chimney.
Before you begin installation, you must determine which chimney installation
will be used.

The Telescopic Chimney Kit is adjustable and designed to meet varying
ceiling heights from 8 to 9 feet.  FIGURE 3 illustrates the dimensions of the
rangehood with the optional Telescopic Chimney Kit.  FIGURE 4  illus-
trates the dimensions of the rangehood with the optional Full Width Duct
Cover
.  The body of the rangehood is the same dimensions regardless of
the chimney option used.

25

"

25

"

RANGEHOOD WITH

FULL WIDTH  DUCT  COVER

FIGURE  3

FIGURE  4

The ductrun should not exceed 35 equivalent
feet if ducted with the required minimum of 3
1/4" by 10" rectangular duct or 55 equivalent
feet if ducted with 10" round duct (when
using  Duct Transition Kit  for 48” model
only).   Calculate the length of the ductwork by
adding the equivalent feet in FIGURE 1 for
each piece of duct in the system  An example
is given in FIGURE 2.  For best results, use
no more than three 90

°

  elbows. Make

sure that there is a minimum of 24" of
straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away,
do it as far away from the hood's exhaust
opening as possible.

Summary of Contents for Pro Magnum

Page 1: ...eusedandtheappliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA TABLE DE CUI...

Page 2: ...e appliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box When making th...

Page 3: ...cessaire pourtouslesappareils combustion Suivezlesconseils et mesures de s curit du fournisseur tels que ceux publi s par l Association Nationale de la Sauvegarde contre l Incendie et l Association A...

Page 4: ...gehood could result in damage to the product or personal injury PERSONAL INJURY HAZARD 9 Feet Straight Duct 2 90 Elbows Wall Cap Total System 9 0 feet 10 0 feet 0 0 feet 19 0 feet FIGURE 2 3 0 feet 5...

Page 5: ...angehood must be turned to the rear The dimensions for the duct openings are given in FIGURE 8 The 48 model uses two 3 1 4 by 10 duct openings Install all ductwork before installing the rangehood 6 De...

Page 6: ...extend the bracket 6 Install the damper before hanging the rangehood The damper attaches to the rangehood by two small screws provided in the hardware package If 48 hood is to be connected to 10 round...

Page 7: ...s designed to remove smoke cook ing vapors and odors from the cooktop area Rangehood Control Panel The control panel is located on the right hand side under the canopy The position and function of eac...