background image

  

  

Air Switch Assembly and Collar Specifications: 

(located inside range hood ducting) 

Unit Specifications: 
16 AWG x 2, 10A,  24 VAC.  

Refer to full safety instructions prior to 

installation. 

 

¾” 

3 ¼ ” 

6” 

2” 

Motorized Fresh Air Damper Specifications: 

(located in fresh air ducting from outside the home) 

Air Switch 
Assembly 
Available in 
6” and 10”  

Unit Specifications 
Weight: 3 lbs. 
0.25 amps, 24 VAC, 60 HZ, 7 watts.  Shipped in normally 
closed position. 

8

” 

2

 ¾” 

Motorized 

Damper 

Available in 

6” and 10”  

2

 ¾” 

2

 5/8” 

WIRING DIAGRAM for Direct Kitchen Connection (

not used for HVAC system connection

): 

WARNING

:

 

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK HAZARD,  

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:   

1.

Shut off and disconnect all power supply to unit(s) prior to installation or service/repair of device.   

2.

Use this unit only in manner intended by manufacturer. 

3.

All applications of device must follow all applicable laws, codes, regulations, and standards. 

4.

Installation of device must be completed by a certified installation expert or HVAC professional. 

5.

For residential use only, any use beyond factory recommendations voids all warranties. 

 

Air Switch 
Assembly 

24 VAC Power 
Transformer 

Line 
Volts 

Motorized Fresh 
Air Damper 

Circuit Setup 

1.

Using a 24 Volt Class 2 Transformer, Take one Open terminal and Connect to the Motorized Damper. 

2.

Still Using the 24 Volt Transformer, Take the other Open Terminal and Connect to the Air Switch Assembly. 

3.

Lastly Take the Second Open Terminal from Switch Assembly and Connect to The Motorized Damper’s other 
Open terminal, therefore completing the Circuit. 

Summary of Contents for MUDAMPER6

Page 1: ...ay to fresh air is provided 7 This unit is intended to be installed within the home in a location protected from any kind of moisture 8 Do not connect this kit directly to any combustion appliances 9...

Page 2: ...p air system or through natural air infiltration Return Air Duct Air Circulation Fan Filter Air Supply Duct Kitchen Range Hood Switch Assembly Motorized Fresh Air Damper Fresh Air Intake on Exterior o...

Page 3: ...and allergens drawn in with the outside air The replenishment or make up air must be drawn from outside of the home 24V low voltage wiring required at initial rough in stage of installation wiring not...

Page 4: ...Vertical Ducting Installation Inline Blower Installation Inline Fan Motor Remote Blower Installation Exterior Mounted Fan Motor Downdraft Fan Motor Direct Rear Ducting Installation Air Switch Installa...

Page 5: ...sconnect all power supply to unit s prior to installation or service repair of device 2 Use this unit only in manner intended by manufacturer 3 All applications of device must follow all applicable la...

Page 6: ...per closes when the range hood motor is turned off Your Faber range hood will operate effectively since there is an adequate supply of fresh air to draw from DOES MY FURNACE OR WATER HEATER GET COMBUS...

Page 7: ...qu et une voie claire l air frais est fourni This unit is intended to be installed within the home in a location protected from any kind of moisture 7 Ne pas brancher ce kit directement tous les appar...

Page 8: ...de l air naturel Alimentation en air Fan de Circulation d air Filtrez Fourniture d air Hotte Mettez Assembl e Motoris frais air Damper Frais d admission d air sur l ext rieur de la maison Le sch ma d...

Page 9: ...rg nes tir en l air l ext rieur La reconstitution ou l air d appoint doivent tre tablis l ext rieur de la maison 24V c blage basse tension n cessaire au stade initial rugueux dans l installation c bla...

Page 10: ...tion du Ventilateur Moteur mont dans une ligne de ventilateur Installation Ventilateur Distance Gendarmerie ext rieur du moteur du ventilateur Bas projet de moteur de ventilateur Direct Installation C...

Page 11: ...l unit s avant l installation ou l entretien r paration de l appareil 2 Utiliser cet appareil uniquement de la mani re pr vue par le fabricant 3 Toutes les applications de dispositif doivent suivre to...

Page 12: ...sque le moteur de la hotte est teint Votre hotte Faber va fonctionner efficacement car il ya un nombre suffisant d air frais tirer Est ce que ma fournaise ou un chauffe eau p n trer air de combustion...

Reviews: