Air Switch Assembly and Collar SpecificaIons:
(located inside range hood duc9ng)
Unit Specifica9ons:
16 AWG x 2, 10A, 125VAC.
Refer to full safety instrucIons prior to
installaIon.
¾”
3 ¼ ”
6”
2”
Motorized Fresh Air Damper SpecificaIons:
(located in fresh air duc9ng from outside the home)
Air Switch
Assembly
Available in
6” and 10”
Unit Specifica9ons
Weight: 3 lbs.
0.25 amps, 24 VAC, 60 HZ, 7 wads. Shipped in normally
closed posi9on.
8
”
2
¾”
Motorized
Damper
Available in 6”
and 10”
2
¾”
2
5/8”
5
WIRING DIAGRAM for Direct Kitchen Connec9on (
not used for HVAC system connecIon
):
WARNING
:
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK HAZARD,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.
Shut off and disconnect all power supply to unit(s) prior to installa9on or service/repair of device.
2.
Use this unit only in manner intended by manufacturer.
3.
All applica9ons of device must follow all applicable laws, codes, regula9ons, and standards.
4.
Installa9on of device must be completed by a cer9fied installa9on expert or HVAC professional.
5.
For residen9al use only, any use beyond factory recommenda9ons voids all warran9es.
Air Switch
Assembly
24 VAC Power
Transformer
Line
Volts
Motorized Fresh
Air Damper
Circuit Setup
1.
Using a 24 Volt Class 2 Transformer, Take one Open terminal and Connect to the Motorized Damper.
2.
SIll Using the 24 Volt Transformer, Take the other Open Terminal and Connect to the Air Switch Assembly.
3.
Lastly Take the Second Open Terminal from Switch Assembly and Connect to The Motorized Damper’s other
Open terminal, therefore compleIng the Circuit.