LED indicator light (I) - indicates current speed with color

Green    

- speed 1

Orange   

- speed 2

Red  

 

- speed 3

Flashing Red  

- intensive speed

Light On/Off Button ( L )

On/Off switch for the halogen lights. Press the button to turn the light ON and press again 

to turn it OFF.

Blower On/Off Button ( T1 )

On/Off button for the blower. Press the button to turn the blower ON to speed one (indi-

cated by green LED) and press again to turn the hood off

Blower Speed 2 (T2)

Press this button to turn the hood onto speed #2. (indicated by orange LED)

Blower Speed 3 / Intensive (T3)

Press this button to turn the hood onto speed #3. (indicated by solid red LED) Hold down 

the speed 3 button for 2 seconds to activate the intensive speed. The intensive speed set-

ting is indicated by a blinking red light. This operates the hood for 6 minutes on the highest 

speed and then returns to the previous speed.

For Best Results

Start the rangehood several minutes before cooking to develop proper airflow. Allow the 

unit to operate for several minutes after cooking is complete to clear all smoke and odors 

from the kitchen.

Summary of Contents for MAESTRALE MAES3018SS600-B

Page 1: ...OSTR30SS400 OSTR36SS400 Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien OSTRO...

Page 2: ...with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING...

Page 3: ...d be installed to minimize backward cold air flow and a nonmetallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on...

Page 4: ...or grounding DO NOT ground to a gas pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in electrical shock Check with a qualified elect...

Page 5: ...5 RANGEHOOD DIMENSIONS RANGEHOOD DIMENSIONS WITH OPTIONAL FULL CHIMNEY RANGEHOOD DIMENSIONS WITH OPTIONAL TELESCOPIC CHIMNEY 29 15 16 35 3 4 29 15 16 35 3 4 29 15 16 35 3 4...

Page 6: ...Recirculation Kit DUCTGRT30 36 Recirculation Kit DUCTGRT36 Created by Denomination Lang EN Sheet1 1 Modif by Approved by Approval date Doc status Drawing N NEW_DRAWING_BOX Rev 01 10 1 12a 14 13 11b 6...

Page 7: ...e lters Turn the knob to the left coun terclockwise to release lter Repeat with other lter Reinstall the lter by placing the back edge in the channel at rear of hood Push lter into place turn the knob...

Page 8: ...8 Ducted Venting Options Installation Horizontal Vertical 6 6 Rear 6 Ducting Methods...

Page 9: ...r from the body of the Hood and position it so the transition opening is facing to the rear wall from the back remove and rotate 180 degrees to the left and then flip it back 90 degrees as shown in th...

Page 10: ...uct work must be installed to exhaust the rangehood back into the kitchen either at the top of the cabinet FIGURE 3A or at the face or side of the soffit FIGURE 3B Install at least 15 of metal duct fi...

Page 11: ...mounting on the Wall Draw a vertical line on the supporting wall as high as practical at the center of the area in which the hood will be installed Draw a horizontal line at where the bottom edgeofth...

Page 12: ...and at L distance on the left and right of vertical line The distance L change for all dimension of Hood Insert the two wall plugs in the holes as shown and fix 3 4 E E Hookthehoodbodyontothewallplug...

Page 13: ...wo remaining screws to anchor the hood in holes If your installation uses the optional duct cover t the cover anges over the brackets If installation uses the telescopic chimney extension t the extens...

Page 14: ...arked Insert the purchased wall plugs in the holes Using two remaining screws to anchor the hood in holes 1 3 4 12a 13 2 6 x 14 Non Ducted Recirculation Option For Non Ducted Recirculation venting rou...

Page 15: ...d 19 15 32 B Mounting brackets C Top of hood 2 Install each bracket on the wall as shown Make sure the screws and brackets are securely fastened to the wall IMPORTANT Install only the brackets Do not...

Page 16: ...re for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING...

Page 17: ...ff Blower Speed 2 T2 Press this button to turn the hood onto speed 2 indicated by orange LED Blower Speed 3 Intensive T3 Press this button to turn the hood onto speed 3 indicated by solid red LED Hold...

Page 18: ...ted and must be replaced approximately every 4 months of operation ormorefrequentlyforparticularlyheavyusage Remove the Filters one at a time pushing them towards the back of the unit and at the same...

Page 19: ...on Creation date 16 Feb 2018 CORRADO DOLCE Created by 991 0349 116 Code 220 240V 50Hz 220 60Hz 110 127V 60Hz F N BLU PNK BRW WHT 1 2 3 4 5 6 BLK Y G 1 2 3 6 5 4 9 8 7 PNK M8 4V BRW ORG M1 V1 MC F V2 E...

Page 20: ...om accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products not approved...

Page 21: ...nevoiedesortiesetrouvederri revouspendantquevous teignezlesflammes D apr sleguide KitchenFiresafetyTips publi parlaNFPAaux tats Unis AVERTISSEMENT POURR DUIRELERISQUED INCENDIEOUDECHOC LECTRIQUE n uti...

Page 22: ...ences en mati re de ventilation pourrait entra ner un incendie AVERTISSEMENT Installation dans les climats froids Le syst me de ventilation doit pr voir un registre antirefoulement suppl mentaire pour...

Page 23: ...ILISEZ PAS une conduite de gaz pour la mise la terre N INSTALLEZ PAS un fusible sur le circuit neutre ou le circuit de mise la terre La pr sence d un fusible dans le circuit neutre ou de mise la terre...

Page 24: ...24 DIMENSIONS DE LA HOTTE DIMENSIONS DE LA HOTTE AVEC CHEMIN E COMPL TE EN OPTION DIMENSIONS DE LA HOTTE AVEC CHEMIN E T LESCOPIQUE EN OPTION 29 15 16 35 3 4 29 15 16 35 3 4 29 15 16 35 3 4...

Page 25: ...pleine largeur No d article FULL36 Recouvrement de canalisation de chemin e t lescopique TELEMAES R ducteur de d bit accessoire CFMRED2 Filtre charbon actif No d article FILTER1 30 Recirculation Kit D...

Page 26: ...a gauche sens contraire des aiguilles d une montre pour d gager le filtre R p tez l op ration avec l autre filtre R installez le filtre en pla ant son rebord arri re dans la rainure l arri re de la ho...

Page 27: ...27 6 6 6 Arri re Horizontale Verticale Options d installation avec ventilation canalis e M thodes de canalisation...

Page 28: ...la hotte et placez le de fa on ce que l ouverture de passage de l air se trouve face au mur arri re d gagez le de l arri re et faites le tourner de 180 degr s vers la gauche puis inclinez le de 90 de...

Page 29: ...UCTGRT36 36 2 Une canalisation doit tre install e pour vacuer la hotte dans la cuisine soit au sommet des armoires FIGURE 3A ou sur la face ou le c t du parement FIGURE 3B Installez un conduit m talli...

Page 30: ...acez une ligne verticale sur le mur d appuileplushautquepossible aucentre del emplacemento lahotteserainstall e Tracez une ligne horizontale l endroit correspondant au bas de la hotte comme repr sent...

Page 31: ...e et gauche de la ligne verticale La distance L varie en fonction de la dimension de la hotte Ins rez les deux chevilles dans les orifices comme illustr et fixez les 3 4 E E Engagez le b ti de la hott...

Page 32: ...ancrer la hotte Si votre installation pr voit le recouvrement de canalisation en option placez les flasques du rev tement sur les brides Si l installation pr voit le prolongement de chemin e t lescopi...

Page 33: ...hevilles achet es dans les trous Ins rez les deux vis restantes dans les trous inf rieurs pour ancrer la hotte au mur 12a 13 6 x 14 Option non canalis e avec recyclage d air Pourlaventilationavecrecyc...

Page 34: ...e C Haut de la hotte 2 Installez chaque bride sur le mur comme illustr Assurez vous que les vis et brides sont solidement ancr es au mur IMPORTANT Installez les brides uniquement N installez pas la ho...

Page 35: ...n au courant lectrique Cet appareil est muni d un cordon pr sentant un fil de mise la terre avec une fiche de mise la terre La fiche doit tre ins r e dans une prise correctement install e et mise la t...

Page 36: ...entilateur 2 T2 Appuyez sur ce bouton pour activer le capot sur la vitesse 2 indiqu par LED orange Vitesse du ventilateur 3 Intensif T3 Appuyez sur ce bouton pour activer la hotte sur la vitesse 3 ind...

Page 37: ...avable et ne peut pas tre r g n r Il doit tre remplac environ tous les 4 mois d utilisation ou plus souvent en cas d utilisation particuli rement intensive Retirez les filtres un un en les poussant ve...

Page 38: ...ion Creation date 16 Feb 2018 CORRADO DOLCE Created by 991 0349 116 Code 220 240V 50Hz 220 60Hz 110 127V 60Hz F N BLU PNK BRW WHT 1 2 3 4 5 6 BLK Y G 1 2 3 6 5 4 9 8 7 PNK M8 4V BRW ORG M1 V1 MC F V2...

Page 39: ...es d coulant d un accident d une modification de l utilisation incorrecte ou abusive d un incendie d une inondation d un cas de force majeure d une installation inad quate d une installation non confo...

Page 40: ...991 0533 513_02 180221 D0004468_01...

Reviews: