RECOMMENDATIONS AND SUGGESTIONS

 

  The Instructions for Use apply to several versions of this appliance. Accordingly, you may 

find descriptions of individual features that do not apply to your specific appliance. 

INSTALLATION 

•  The manufacturer will not be held liable for any damages resulting from incorrect or im-

proper installation. 

•  The minimum safety distance between the cooker top and the extractor hood is 650 mm 

(some models can be installed at a lower height, please refer to the paragraphs on work-

ing dimensions and installation). 

•  Check that the mains voltage corresponds to that indicated on the rating plate fixed to the 

inside of the hood. 

•  For Class I appliances, check that the domestic power supply guarantees adequate 

earthing. 

  Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. 

The route of the flue must be as short as possible. 

•  Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, 

fireplaces, etc.). 

•  If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appli-

ances), a sufficient degree of aeration must be guaranteed in the room in order to prevent 

the backflow of exhaust gas. The kitchen must have an opening communicating directly 

with the open air in order to guarantee the entry of clean air.

 

When the cooker hood is 

used in conjunction with appliances supplied with energy other than electric, the negative 

pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into 

the room by the cooker hood. 

•  In the event of damage to the power cable, it must be replaced by the manufacturer or by 

the technical service department, in order to prevent any risks. 

USE 

•  The extractor hood has been designed exclusively for domestic use to eliminate kitchen 

smells. 

•  Never use the hood for purposes other than for which it has been designed. 

•  Never leave high naked flames under the hood when it is in operation. 

•  Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it 

does not engulf the sides. 

•  Deep fat fryers must be continuously monitored during use: overheated oil can burst into 

flames. 

•  Do not flambè under the range hood; risk of fire  

•  This appliance is not intended for use by persons (including children) with reduced physi-

cal, sensory or mental capabilities, or lack of experience and knowledge, unless they have 

been given supervision or instruction concerning use of the appliance by a person respon-

sible for their safety. 

•  Children should be supervised to ensure that they do not play with the appliance. 

•  “ CAUTION: Accessible parts may become hot when used with cooking appliances.”. 

MAINTENANCE 

•  Switch off or unplug the appliance from the mains supply before carrying out any mainte-

nance work. 

•  Clean and/or replace the Filters after the specified time period (Fire hazard). 

•  Clean the hood using a damp cloth and a neutral liquid detergent. 

 

The symbol 

 on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be 

handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of 
correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by 
inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your 
household waste disposal service or the shop where you purchased the product

 

Summary of Contents for Lithos

Page 1: ...INSTRUCTIONS MANUAL EN LITHOS...

Page 2: ...er to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Neve...

Page 3: ...opy complete with Controls Light Fan unit Fil ters 2 1 Telescopic chimney comprising 2 1 1 Upper chimney 2 2 1 Lower chimney 9 1 Reduction flange 150 120 mm 14 1 2 Air Outlet Connector Extension 15 1...

Page 4: ...vided aligning its centre grooves with the vertical reference line Mark the centres of the holes in the bracket Mark a reference point as indicated at 105 mm from the horizontal reference line Drill t...

Page 5: ...120 mm air exhaust connection insert the re ducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove possible charcoal filters 150 9 120 RECIR...

Page 6: ...pen the two side pieces out slightly hook them up behind the brackets 7 2 1 and bring them back together again until they are in contact Fix to the Brackets at the sides using 4 screws 12c 2 9 x 9 5 p...

Page 7: ...Fixed When pressed briefly turns the Motor on at Speed three Flashing Pressed for 2 Seconds Activates Speed four with a timer set to 10 minutes after which it returns to the speed that was set previou...

Page 8: ...the handle is visible on the outside Activated charcoal filter Recirculation version These filters are not washable and cannot be regenerated and must be replaced approximately every 4 months of opera...