Faber INCA Installation Instructions Manual Download Page 5

Version 11/98 - Page 5

INSTALL  THE  RANGEHOOD

1. 

Remove the rangehood from the carton and place on a 

flat surface.  Cover the surface to prevent accidental damage.  

Remove all parts including the backdraft damper, 2 screws, 

and literature package before discarding the carton.

2. 

Remove the grease filters from the rangehood and set 

aside.  The grease filters are removed by pressing the handle 

of the filter as indicated in FIGURE 7.  When replacing, make 

sure that the filters are properly positioned with the handles 

in front and visible.

3. 

Remove the cover from the field wiring compartment.  

Remove  the  wiring  electrical  knockout  using  a  flat-blade 

screwdriver.    Feed  the  Power  Supply  Cable  through  the 

electrical knockout.

4.

  Attach the damper to the exhaust opening of the range-

hood.  Two small phillips screws are provided to attach the 

damper.  

5. 

The rangehood mounts to the cabinet by two spring 

loaded brackets, one on each side of the rangehood.  Lift the 

rangehood into the cutout opening in the cabinet.  Be careful 

not to damage the cabinet, rangehood or other appliances. 

PREPARE  THE  WALL

1. 

Disconnect and move freestanding range from cabinet 

opening to provide easier access to upper cabinet and rear 

wall.  Put a thick, protective covering over cooktop, set-in 

range or countertop to protect from damage or dirt.

2. 

Determine and clearly mark with a pencil the center line 

on the cabinet where the rangehood will be installed.

3. 

Determine and make all necessary cuts in the wall for 

the ductwork.  Install the ductwork before the rangehood.

4. 

Determine the proper location for the Power Supply 

Cable.  Use a 1 & 1/4" Drill Bit to make this hole.  Install the 

cable.  Use caulking to seal around the hole.  DO NOT turn 

on the power until installation is complete.

RECIRCULATING INSTALLATIONS

For recirculating installations, filter kit 6093037 is neces-

sary.  The charcoal filter must be inserted behind the 

grease filters.  Recirculating installations also require some 

duct work to divert the air out of the cabinet.  The duct work 

must not terminate inside the cabinet.

CALCULATE  THE  DUCTRUN  LENGTH

The length of the ductrun should not exceed the 26 equivalent feet.  

The equivalent length is calculated by adding the actual straight length 

of duct to the equivalent feet of elbows and wall caps.  Calculate the 

length of the ductwork by adding the equivalent feet listed in FIGURE 

5 for each piece of duct in the complete system.  FIGURE 6 gives 

an example of how to calculate the equivalent length.

For best results, use no more than three 90°  elbows.  Make sure 

that there is a minimum of 24" of straight duct between elbows if 

more than one is used.  Do not install two elbows together.  

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap
Total System

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE  6

7.0 feet

5.0 feet

12.0 feet

0.0 feet

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE  5

TOOLS  NEEDED  FOR  INSTALLATION

 

• Saber Saw or Jig Saw

 

• Drill

 

• 1  1/4" Wood Drill Bit

 

• Pliers

 

• Phillips Screwdriver

 

• Flat Blade Screwdriver

 

• Wire Stripper or Utility Knife

 

• Metal Snips

 

• Measuring Tape or Ruler

 

• Level

 

• Pencil

 

• Caulking Gun

 

• Duct Tape

PARTS  SUPPLIED  FOR  INSTALLATION

 

• 1 Backdraft Damper

 

• 2 Screws

 

• 1 Literature Package

PARTS  NEEDED  FOR  INSTALLATION

 

• 2 Conduit Connectors

 

• Power Supply Cable

 

• 1 Wall or Roof Cap

 

• All Metal Ductwork

FIGURE 7

FIGURE  8

6. 

Tighten  the  rangehood  to  the  cabinet  by  rotating 

the screws indicated in FIGURE 8 with a flat blade screw 

driver.

7. 

Connect the Power Supply Cable to the rangehood.  

Attach the White lead of the power supply to the White lead 

of the rangehood with a twist-on type wire connector.  Attach 

the Black lead of the power supply to the Black lead of the 

rangehood with a twist-on type wire connector.  Connect the 

Green ( Green and Yellow ) ground wire under the Green 

grounding screw.

8. 

Replace the field wiring compartment cover and grease 

filters.

9.

  Connect the ductwork to the damper and seal all con-

nections with duct tape.

10.

  Turn the power supply on.  Turn on the blower and light.  

If the rangehood does not operate, check that the circuit breaker 

is not tripped or the house fuse blown.  If the unit still does 

not operate, disconnect the power supply and check that the 

wiring connections have been made properly.

Summary of Contents for INCA

Page 1: ...installation of this rangehood must conform to the Manufactured Home Construction and Safety Standards Title 24 CFR Part 3280 formerly Federal Standard for Mobile Home Construction and Safety Title 24...

Page 2: ...uit breaker through exible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever nec essary AULListed 1 2 conduit connector must...

Page 3: ...ieur Si elle est installer au dessus d une baignoire ou une douche pr voir ce qu elle soit conforme cet usage A n d obtenir un rendement maximal en ce qui a trait la combustionainsiqu l vacuationdesga...

Page 4: ...RANGEHOOD DIMENSIONS CUTOUT DIMENSIONS FIGURE 4 Version 11 98 Page 4 FIGURE 1 FIGURE 2 WIDTH A 27 7 8 DEPTH B 13 1 8 FIGURE 3...

Page 5: ...f the cabinet The duct work must not terminate inside the cabinet CALCULATE THE DUCTRUN LENGTH Thelengthoftheductrunshouldnotexceedthe26equivalentfeet Theequivalentlengthiscalculatedbyaddingtheactuals...

Page 6: ...ght To replace the uorescent light remove the retainer clips T from both ends of the glass diffuser as indicated in FIGURE 10 Carefully slide the glass all the way to one end Lower the opposite end of...

Page 7: ...DIMENSIONS DE LA HOTTE FIGURE 1 DIMENSIONS DE LA COUPE FIGURE 2 LARGEUR A 27 7 8 PO HAUTEUR B 13 1 8 PO FIGURE 3 FIGURE 4 Version 11 98 Page 7...

Page 8: ...s avant la hotte 4 D terminer l emplacement appropri pour le c ble d alimentation Utiliser une m che de 1 1 4 po pour faire un trou et y passer le c ble d alimentation Utiliser du calfeutrage pour sce...

Page 9: ...marche arr t du ventilateur M Interrupteur marche arr t pour le ventilateur R gler 1 pour mettre en circuit ON et O pour mettre hors circuit OFF Bouton de vitesse du ventilateur V R glage de la vites...

Page 10: ...4324292...