Faber Fyn 450 ENG Installation Manual Download Page 18

                                                                                                                                              

17 < 

<

 

<

 

<

 

 

14

 

 Technical data 

Technical data 

Type indication(s) 

Farum, Fyn, Fyn 450, Concept I-450 

Type appliance 

C11/C31/C91 

Diameter outlet/inlet 

100/150 

Gas connection 

3/8" 

Indirect heating functionality 

no 

Category 

II2H3+ 

  

Symbol 

  

  

  

  

Unit 

 Reference gas/inlet pressure 

  

  

G20-20 

G30-30 

G31-37 

mbar 

Emissions in space heating 

NOx 

  

78 

88 

85 

mg/kWh

input   

(GVC) 

Direct heating output 

  

  

  

  

  

  

Nominal heat output 

P

nom

 

  

4,2 

3,9 

3,9 

kW 

Minimum heat output (indicative) 

P

min

 

  

1,5 

1,4 

1,4 

kW 

Useful efficiency (NCV) 

  

  

  

  

  

  

At nominal heat output 

th,nom

 

  

93,7 

93,7 

93,7 

At minimum heat output (indicative) 

th,min

 

  

89,7 

89,7 

89,7 

Appliance input data 

  

  

  

  

  

  

Input 

Hi 

  

4,5 

4,2 

4,2 

kW 

Gas rate at full mark 

  

  

0,482 

0,127 

0,164 

m³/h 

  

  

320 

310 

kg/h 

Burner pressure at full mark 

  

  

10 

24,8 

31,6 

mbar 

Power requirement for permanent pilot 

light 

  

  

  

  

  

  

Power requirement for permanent pilot 

light            (if applicable) 

P

pilot

 

  

0,11 

0,11 

0,11 

kW 

Additional electricity consumption  

  

  

  

  

  

  

At nominal heat output 

el

max

 

  

kW 

At minimum heat output 

el

min

 

  

kW 

In standby mode 

el

SB

 

  

kW 

Energy-efficiency 

  

  

  

  

  

  

Energy-efficiency class 

  

  

  

Energy-efficiency index  

EEI 

  

88 

88 

88 

  

Type heating output/control room 

temperature 

  

  

Other control options 

One step heat output, no control of room 

temperature 

no 

Control of room temperature, 

with presence detection 

no 

Two or more manually adjustable stages, no 

control of room temperature 

no 

With mechanical control of the room temperature 

by thermostat 

no 

Control of room temperature, 

with open window detection 

no 

With electronic control of the room temperature 

no 

With electronic control of the room temperature 

plus day-time switch 

yes 

With optional remote control 

yes 

With electronic control of the room temperature 

plus week-time switch 

no 

Glen Dimplex Benelux  Saturnus 8 Heerenveen The Netherlands  

Summary of Contents for Fyn 450 ENG

Page 1: ...Installation manual Fyn 450 ENG 40010929 1840...

Page 2: ...1 L 1 1 1 2 1 3 1 4 1 5 1 6 2 1 2 2 2 3...

Page 3: ...2 L 3 1 3 2 4 0 4 1 4 2 4 3 4 4...

Page 4: ...ome hotter than 100 C Do not use the remote control and or app outside the room where the fire is located So that you are always aware of the situation around the fireplace when it is being operated C...

Page 5: ...p a free distance of min 50mm on the back site of the fire See fig 1 1 For the finish use special stucco min 100 C resistant or glass fibre wallpaper to prevent discoloration or cracks etc Recommended...

Page 6: ...100mm should have a CE mark for temperatures up to 600 Celsius The chimney should comply with the following requirements The diameter of the flue system must be at least 150x150mm There should be no m...

Page 7: ...rizontal parts must be installed at a 3 degree slope up away the appliance Build up the system from the appliance If this is not possible you should make use of an adjustable pipe For fitting the syst...

Page 8: ...e appliance is used 6 Placing the decorative material It is not allowed to add different or more materials to the combustion chamber Always keep the pilot burner free from decorative material Do not t...

Page 9: ...and easily 7 2 Checking for gas leakage Check all connections and joins for possible gas leaks by means of a gas leak detector or spray 7 3 Checking the burner pressure and the pre pressure Check whe...

Page 10: ...leakage in case of blue flames Whether the correct flue restrictor has been mounted The outlet o Wall terminal is installed correctly o Roof terminal is fitted and sited correctly The flue system is c...

Page 11: ...ed with a dry cloth Clean the glass with Faber glass polish Note prevent fingerprints on the glass these will be burned into it once the appliance is used and cannot be removed anymore Carry out the c...

Page 12: ...HL Start length STL This is the first part that is placed on the fire and represents a certain value fig 12 1 12 2 and 12 3 A N and F This value is in the top row of the table see restrictor table 11...

Page 13: ...gle of 30 or 45 fig 12 1 C Fill in only in combination with at least 2x 30 or 45 bends in the vertical part Restrictor table See the restrictor table at the right vertical TVH and horizontal length TH...

Page 14: ...0 40 x x x x 10 65 1 65 65 60 60 50 40 x x x x 11 65 1 65 65 60 60 50 40 x x x x 12 65 1 65 65 60 60 50 40 x x x x 13 65 1 65 65 60 60 50 40 x x x x 14 65 1 65 65 60 60 50 40 x x x x 15 65 1 65 65 60...

Page 15: ...14 L 12 Examples flue materials Fig 12 1 Fig 12 2 Fig 12 3...

Page 16: ...Bend in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Calculation Total rounded value Total Vertical Height TVH measured height meter Total Horizontal Length THL Value Starter...

Page 17: ...er to 130 200 and 1 meter 130 200 after that reduce to 100 150 and everything 100 150 0 5 Restrictor size Value for the comma Extra information Value behind the comma Search in the table at TVH and TH...

Page 18: ...er requirement for permanent pilot light if applicable Ppilot 0 11 0 11 0 11 kW Additional electricity consumption At nominal heat output elmax 0 0 0 kW At minimum heat output elmin 0 0 0 kW In standb...

Page 19: ...ance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable out...

Page 20: ...19 L 16Troubleshooting guide...

Page 21: ...20 L...

Page 22: ...21 L...

Page 23: ...22 L 17Dimensional drawings 17 1 Fyn 450...

Page 24: ...23 L 17 2 Ventilation grid...

Page 25: ...24 L 17 3 Remote access door...

Page 26: ...25 L...

Page 27: ...26 L...

Page 28: ......

Reviews: