2. GENERAL INFORMATION
INSTALLATION
CAUTION:
THIS APPLIANCE MUST BE EARTHED
1. All the plumbing work should be completed before proceeding to electrical wiring connection.
(Table 1)
2. Installation must be carried out by a qualified electrician with close reference to the operation
manual and in compliance with the local regulations.
3. The unit works at minimum water flow rate of 2 litre/min, which then would trigger the bulit-in
pump (only for pump model), boostering a stronger shower spray.
4. The bulit-in electronic Earth Leakage Circuit Break (ELCB) would cut-off the power supply to
the heater in the event of current leakage of as low as 15mA.
5. The Thermal Cut-Off would automatically shut off the power supply shall there be any abnormal
rise of showering temperature.
6. The unit only operates when there is sufficient water flow to trigger the flow switch.
7. Electrical loading Table 1:
8. Instantaneous water heater’s shall be equipped with a 2 pole control switch and is own residual
current device.
9. Water heaters exceeding 3kW shall be permanently connected to a 20A/30A rated circuit breaker
/ fuse with an isolator switch and residual current device.