background image

FWH SOTTILE 306
FWH SOTTILE 307
FWH SOTTILE 308AC
FWH SOTTILE 309DC 

INSTANT WATER HEATER

MODEL: SOTTILE SLIM SERIES 

USER MANUAL

1

Summary of Contents for FWH SOTTILE 306

Page 1: ...FWH SOTTILE 306 FWH SOTTILE 307 FWH SOTTILE 308AC FWH SOTTILE 309DC INSTANT WATER HEATER MODEL SOTTILE SLIM SERIES USER MANUAL 1...

Page 2: ...unit 5 Do not connect the OUTLET to any tap or fitting that is not recommended by the manufacturer 6 Do not block the heater OUTLET in any way 7 Do not attempt to repair the heater without qualified t...

Page 3: ...Water INLET Connection Water OUTLET Connection Heater Control Unit Triac Heater Tank Thermal Cut Out LED Display Board ABS Heater Base ELCB Control Board ABS Front Cover Power LED Heater LED Temperat...

Page 4: ...1 CHROME WHITE ACCESSORIES G1 2 150mm Flexible Hose Wall Bracket Shower Holder Hand Shower Wall Bracket Slider Railbar SHOWER SET ACCESSORIES IDENTIFICATION...

Page 5: ...ower and lower tube with divider Slide down and hook the assembled diverter to the mounted square bracket Tighten the screws and make sure all joints are completely connected to avoid leakage Rain Sho...

Page 6: ...shower spray 4 The bulit in electronic Earth Leakage Circuit Break ELCB would cut off the power supply to the heater in the event of current leakage of as low as 15mA 5 The Thermal Cut Off would autom...

Page 7: ...et above the floor to bottom of the heater Diagram 1 4 Mark mounting position Diagram 2 Remove screw at the bottom of the heater Lift the plastic cover upward Mark mounting position on the wall Drill...

Page 8: ...direction to MAX and return to OFF mark as shown Diagram 5 Test Run Of Heater a Turn on the stop valve and water should spray out from shower head b Switch on the main power supply POWER LED would lig...

Page 9: ...rmal cold shower just turn the Temperature Control Knob to OFF position 5 Switch off the power supply when not in use DO NOT USE THINNER ALCOHOL OR PETROL CLEAN FILTER REGULARLY Diagram 6 You may clea...

Page 10: ...P FWH SOTTILE 309DC 3 6kW 240V 50 60Hz Notes The specification actual product s design and accessories parts shown are correct at the time of printing and subject to change without prior notices 6 TEC...

Page 11: ...11 AC PUMP FWH SOTTILE 308AC NON PUMP FWH SOTTILE 306 307...

Page 12: ...12...

Reviews: