ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit.
A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local
codes in accordance with the electrical rating of this unit as specified on the serial/rating
plate located inside the unit near the field wiring compartment.
• Electrical ground is required on this Range Hood.
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other
materials, DO NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral
or grounding circuit could result in electrical shock.
• Check with a qualified electrician if you are in doubt as to whether the Range
Hood is properly grounded.
• Failure to follow electrical requirements may result in a fire.
WARNING
!
State of California Proposition 65 Warning (US only)
WARNING
This product contains chemicals known to the State of California to cause cancer
and birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
Summary of Contents for FLEXA FLEX24SS300
Page 6: ...6 RANGE HOOD DIMENSIONS RANGE HOOD 24 DRAFT 09 APR 2021 19 45...
Page 7: ...7 RANGE HOOD 30 DRAFT 09 APR 2021 19 39...
Page 8: ...8 INSTALLATION HEIGHT REQUIREMENTS MIN 24 OVER ELECTRIC MIN 30 OVER GAS Min 24 Min 30...
Page 10: ...10 A C B E D...
Page 32: ...32 DIMENSIONS DE LA HOTTE HOTTE DE CUISINE 24 POUCES DRAFT 09 APR 2021 19 45...
Page 33: ...33 HOTTE DE CUISINE 30 POUCES DRAFT 09 APR 2021 19 39...
Page 36: ...36 A C B E D...
Page 58: ...58 DIMENSIONES DE LA CAMPANA EXTRACTORA CAMPANA EXTRACTORA DE 24 DRAFT 09 APR 2021 19 45...
Page 59: ...59 CAMPANA EXTRACTORA DE 30 DRAFT 09 APR 2021 19 39...
Page 62: ...62 A C B E D...