Removing glass 

5.1

 

e-MatriX mood RD 

 
Front glass (see fig. 1.0, provide service from this 
side). 

 

Rotate both glass clamps clockwise.  
See fig. 2.0a and 2.0b. 

 

Place the suction cups and remove the 
front glass. See fig. 2.0c. 

 
For replacing the glass repeat the steps in reverse 
order. 
 
Second front glass 
For cleaning only it’s not necessary to remove this 
glass. 

 

Rotate both glass clamps clockwise.  
See fig. 2.2a and 2.2b. 

 

Place the suction cups and remove the 
front glass. See fig. 2.2c. 

 
For replacing the glass repeat the steps in reverse 
order. 
 
Side glass 
For cleaning only it’s not necessary to remove this 
glass. 

 

Place the suction cups and remove the 
glass. See fig. 2.1. 

 
For replacing the glass repeat the steps in reverse 
order. 

5.2

 

e-MatriX mood ST 

 
Front glass (see fig. 1.1, provide service from this 
side) 

 

Remove the cover list. See fig. 2.3a and 
2.3b. 

 

Rotate the glass clamp clockwise.  
See fig. 2.3c. 

 

Place the suction cups and remove the 
glass. See fig. 2.3d. 
 

For replacing the glass repeat the steps in reverse 
order. 
 
Second front glass 
For cleaning only it’s not necessary to remove this 
glass. 

 

Remove the cover list. See fig. 2.4a and 
2.4b. 

 

Rotate the glass clamp clockwise.  

See fig. 2.4c. 

 

Place the suction cups and remove the 
glass. See fig. 2.4d. 

 
For replacing the glass repeat the steps in reverse 
order. 

 

Decoration set 

 

 

Please note! 

To get the right glow effect, the (optional) bot-
tom lighting must be switched on at 100% in-
tensity. 

 
Make sure the ITC-V2 App is connected to the fire, 
see fig. 7.0. 

 

Switch on the glow effect, see fig. 7.1. 

 

Click on the “flame” in the circle, see fig. 
7.1. 

 

Click on the “settings”, see fig. 7.2. 

 

Set “bottom lighting” to maximum, see 
fig. 7.3. 

6.1

 

Log set 

See the included decoration instruction card or 
Chapter 11: 
 

 

Please note! 
Placing the logs is a meticulous job, this deter-
mines the flame distribution. 
Do not let any decoration material fall into 
the outflow (fire) opening. 
The outflow openings may not be completely 
covered. 

 

 

Divide the mini chips over the bottom. 

 

Place the first two logs over the middle 
section in the recesses provided for this. 

 

Place the remaining logs. 

 

Apply the ash material. 

 
Fine tuning of the glow bed 
By placing the decoration chips close together you 
create a real glow bed. 

6.2

 

Pebbles/Acrylic ice 

Spread an even amount of Pebbles or Acrylic-ice on 
the bottom plate. 
 

 

Summary of Contents for e-MatriX mood 800/500 RD

Page 1: ...Installation manual e MatriX mood 800 500 RD e MatriX mood 800 500 ST ENG 40012144 2208 ...

Page 2: ...Installation manual e MatriX mood 800 500 RD ST 2 ...

Page 3: ...Installation manual e MatriX mood 800 500 RD ST 3 1 0 1 1 1 2 1 3 1 4 1 5 ...

Page 4: ...Installation manual e MatriX mood 800 500 RD ST 4 1 6 2 0a 2 0b 2 0c 2 1 2 2a 2 2b 2 2c ...

Page 5: ...Installation manual e MatriX mood 800 500 RD ST 5 2 3a 2 3b 2 3c 2 3d 2 4a 2 4b 2 4c 2 4d ...

Page 6: ...Installation manual e MatriX mood 800 500 RD ST 6 3 0 4 0a 4 0b ...

Page 7: ... A EA non return valve B or connector C 1m pipe D Valve E To be cut from a pipe length of 1 meter F Mesh filter G In line fine filter H Control box I 1 5m pipe J Engine e MatriX mood 1 Safety clip 11x 2 Brackets 2x fine filter 3 Elbow coupling 4x 5 0 ...

Page 8: ...Installation manual e MatriX mood 800 500 RD ST 8 6 0 6 1 6 2 6 3 7 0 7 1 7 2 7 3 8 0a 8 0b ...

Page 9: ...Installation manual e MatriX mood 800 500 RD ST 9 8 1 8 2 8 3 8 4 8 5 8 6 8 7 9 0 ...

Page 10: ...Installation manual e MatriX mood 800 500 RD ST 10 ...

Page 11: ...its design and construction method complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 these cover the essential requirements of EEC Directives 2014 35 EU and 2014 30 EU Product electric fire Opti myst Model e MatriX mood 800 500 RD e MatriX mood 800 500 ST This declaration will become null and void as...

Page 12: ...ted circuit board DD top lighting optional EE bottom lighting optional FF power supply LED GG fan extraction HH fan heating II external water pump optional Lead control cable A from the Engine to the Control box and connect it see fig 1 2 A Connect the supplied extension cable B to the Control box see fig 1 2 B Max cable length from the center of the fire to the left is 1 5m Max cable length from ...

Page 13: ... Loosen the plug connection for this press the retaining clip of the plug Now remove the bottom plate Install LED bottom lighting Lift the bottom plate in the middle and let it rest carefully at the front of the fire See fig 4 0a or 4 0b Insert the plug into the correct connector of the terminal block see fig 3 0 FF and 4 0a or 4 0b and carefully place the bot tom plate Check that the cable will n...

Page 14: ...ass For cleaning only it s not necessary to remove this glass Remove the cover list See fig 2 4a and 2 4b Rotate the glass clamp clockwise See fig 2 4c Place the suction cups and remove the glass See fig 2 4d For replacing the glass repeat the steps in reverse order Decoration set Please note To get the right glow effect the optional bot tom lighting must be switched on at 100 in tensity Make sure...

Page 15: ...ngine see fig 8 0a or 8 0b 5 Disconnect the fill cap by turning it clockwise see fig 8 1 6 Disconnect the transducer cable see fig 8 2 7 Release the clip on both sides and remove the nozzle see fig 8 3 and 8 4 8 Without spilling any water lift up the wa ter sump gently and empty the water sump see fig 8 5 9 The transducer is fixed in the water sump with a plastic clip Push the clip backwards gentl...

Page 16: ...fig 5 0 K is activated the sponge need to be replaced The absorption valve is located on the right front at the bottom of the Engine 1 Take out the sponge 2 Fix the cause of the water leakage and re move any water at the bottom of the en gine 3 Place the new sponge and open the ab sorption valve by pressing down the white clamp Technical data 230 V 240 V Input Figures Full Heat 1955 W 2129 W Half ...

Page 17: ...Installation manual e MatriX mood 800 500 RD ST 17 Dimensional drawings 10 1 e MatriX mood 800 500 RD ...

Page 18: ...Installation manual e MatriX mood 800 500 RD ST 18 10 2 e MatriX mood 800 500 ST ...

Page 19: ...Installation manual e MatriX mood 800 500 RD ST 19 10 3 Control box ...

Page 20: ...Installation manual e MatriX mood 800 500 RD ST 20 10 4 Remote access door article number A9299463 ...

Page 21: ...Installation manual e MatriX mood 800 500 RD ST 21 Decoration instruction card ...

Page 22: ...Installation manual e MatriX mood 800 500 RD ST 22 ...

Page 23: ...Installation manual e MatriX mood 800 500 RD ST 23 ...

Page 24: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Reviews: