background image

Manual e-MatriX 800 

-------------------------------------------------------------------------------------------------------------------------------------- 

11 < 

<

 

<

 

<

 

8

 

Using the fire 

8.1

 

Manual control - behind access door (see fig. 4.0)

 

A = main switch 

 

 

 

 

 

 

 

 

1 = ON/OFF  

 

 

 

 

 

2 = pairing   

 

 

 

 

 

3 = only for maintenance (service engineer)  

 

4 = reduce flame 
5 = increase flame 
6 = reduce fire crackling sound 
7 = increase fire crackling sound 
 

8.2

 

Remote control (see fig. 4.1) 

 

 

1 = OFF 
2 = press once for ON/press twice for glow effect only 
3 = reduce flame 
4 = increase flame 
5 = reduce fire crackling sound 
6 = increase fire crackling sound 

 

8.1.1

 

Pairing the Bluetooth remote 

At the Control box see fig. 4.0: 

 

Turn the main switch in the ON position, 1 beep. 

 

Press the 

 button, 1 beep and the fire will begin to start. 

 

Press the    button,  the fire starts to beep and the LED’s will start to blink on and off.  

 

Press a button on the remote control. The fire will switch off. Now the remote control is paired 
to the fire. 

 

8.3

 

First time water fill 

 

Ensure that all ball valves are open and turn on the water supply. 

 

Switch the fire on by pressing the mains switch to the ON position and pressing the 

 button 

see Chapter 8.1 and 8.2. 

o

 

If the water level is high enough the flames will automatically start after 45 seconds. 

o

 

If the water level isn’t high enough the LED’s continuously to blink twice after 45 
seconds. Press the mains switch to the OFF position, wait 5 seconds and repeat the 
second step above (this process can be needed several times). 

 
8.4

 

Getting the desired flame effect          

 

The fire always starts with minimum flame setting. When desired press the 

 button for 

higher flames. Please give the flame generator time to react to the changes you make.  
!! Increasing the flame height can lead to condensation on the glass. 
 

 

Press the

 and 

 button for the volume of the crackling sound to your desired level. 

The minimum volume of this sound is off. 

 

If the fire is either turned to standby or switched off entirely, it will always revert to the 
minimum flame setting. The sound level will remain the same as the last sound level as set by the 
user.  

 

Summary of Contents for e-MatriX 800

Page 1: ...Manual e MatriX 800 40011677 1742 Manual e MatriX ENG ...

Page 2: ...Manual e MatriX 800 2 Registration plate ...

Page 3: ...Manual e MatriX 800 3 1 0 1 1 1 2a 1 2b ...

Page 4: ...Manual e MatriX 800 4 2 0a 2 0c 2 0b 2 1a 2 1b ...

Page 5: ...Manual e MatriX 800 5 2 1c 2 2 3 0 3 1 4 0 4 1 4 2 ...

Page 6: ...Manual e MatriX 800 6 5 0 ...

Page 7: ...Manual e MatriX 800 7 6 0 7 0 7 1 7 2 7 3 7 4 8 0 ...

Page 8: ...ith the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 these cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC This declaration is invalid if changes are made to the fire 2 Safety instructions Do not use outdoors Do not use in the immediate surroundings of a bath shower or swimming pool ...

Page 9: ...ad the DC cable inside the Engine to the Control box and connect it Max cable length from the center of the fire to the left 1 5m Max cable length from the center of the fire to the right 1 0m Connect the supplied mains lead 4 1 2 Water connection This appliance is equipped with the following overflow protections o Electromechanical valve in the Control box which is sent by an overflow sensor in t...

Page 10: ... not necessary to remove the side glass First remove the front glass see Chapter 5 1 or 5 2 Place a suction cup and remove the side glass see fig 2 2 For replacing the glasses repeat the steps in reverse order 6 Removing fuel bed Never lift up the fuel bed without using the supplied handles Keep these handles for future use Remove the front glass see Chapter 5 1 or 5 2 Cover the frame to avoid scr...

Page 11: ...s are open and turn on the water supply Switch the fire on by pressing the mains switch to the ON position and pressing the button see Chapter 8 1 and 8 2 o If the water level is high enough the flames will automatically start after 45 seconds o If the water level isn t high enough the LED s continuously to blink twice after 45 seconds Press the mains switch to the OFF position wait 5 seconds and ...

Page 12: ...nd or the running hours and therefore can differ from the above mentioned 10 1 1 Cleaning water sump Always press the mains switch to the OFF position and disconnect the power supply see fig 4 0 Never use abrasive cleaners Remove the front glass see Chapter 5 1 or 5 2 Remove the fuel bed see Chapter 6 Disconnect the fill cap by turning it clockwise see fig 5 0 L and 7 0 Disconnect the 2 connectors...

Page 13: ...cer upwards out of its holder Place the new transducers and repeat the steps above in reverse order 10 1 4 Cleaning mesh filter Turn off the water supply Close the ball valves Unscrew the base and clean the filter inside 10 1 5 Replacing in line filter Turn off the water supply Close the ball valves Replace the in line filter Place it in correct alignment there s a flow direction marking on the fi...

Page 14: ...blink once every eight seconds Water level too high Check the electromechanical valve in the Control box e MatriX will not operate the LED s continuously to blink four times Water filling time is too long Switch the mains switch of the Control box to the OFF position and heck all connections on water leakage Close the ball valves and check the mesh filter by unscrewing the base of it to see that i...

Page 15: ...Manual e MatriX 800 15 13 Dimensional Drawings 13 1 e MatriX 800 650 I 13 2 e MatriX 800 650 IIL ...

Page 16: ...Manual e MatriX 800 16 ...

Page 17: ...Manual e MatriX 800 17 13 3 e MatriX 800 650 IIR ...

Page 18: ...Manual e MatriX 800 18 13 4 e MatriX 800 650 III ...

Page 19: ...Manual e MatriX 800 19 13 5 Control box ...

Page 20: ...Manual e MatriX 800 20 13 6 Wall bracket ...

Page 21: ...Manual e MatriX 800 21 13 7 Remote access door ...

Page 22: ...Manual e MatriX 800 22 ...

Page 23: ...Manual e MatriX 800 23 ...

Page 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Reviews: