User manual e-MatriX heat
8 <
<
<
<
Copy heating programs to other days
To copy newly programmed heating programs
(P1-P4) to other days:
Use
◁
and
▷
to select the day which has
to be copied.
Press and hold the
button for 3
seconds and COPY will be displayed;
Use
◁
and
▷
to select the desired day.
Press and hold the
✔
button for 3 seconds
and PASTE will be displayed and confirms
that the heating programs has been
copied.
Press the
button to exit.
Frost Protection Mode
This mode can be used to provide protection
against frost when the fires is switched on. It
maintains a room temperature of 7°C throughout a
24 hour period.
•
With the remote control activated, press
◁
three times to highlight the Frost icon
(
);
•
Press
✔
to activate the Frost Mode;
•
To exit the Frost Mode and enter Manual
Mode automatically, press the
◁
or
▷
button.
Technical data
Troubleshooting and fault codes remote control
Output
230V
240V
Nominal heat output
1.6kW 1.6kW
Minimum heat output
0.8kW 0.8kW
Maximum heat output
1.6kW 1.6kW
In standby mode
5W
5W
Code
Symptom
Cause
Action
The flame effect will not
start.
No power supply.
Low water level.
The transducers) are not
connected properly.
Check if power supply is connected to wall
socket correctly and the mains switch of the
Control box is in the ON (I) position.
See
“First time water fill”, Chapter 4 in user
manual.
Check that the connector(s) is inserted
correctly, see fig. 7.1.
51
e-MatriX will not start or
stopped working and the
LED’s continuously to blink
twice.
Low water level.
The absorption valve (overflow
protection) is activated.
See “First time water fill”, chapter 4.
Switch the mains switch of the Control box to
the “OFF” (0) position, see fig. 4.0-D. Check
all connections on water leakage and t
urn
the mains switch back in the “ON” position.
See installation manual, chapter 9.2.
56
e-MatriX will not operate,
the LED’s continuously to
blink four times.
Water filling time is too long.
Switch the mains switch of the Control box to
the “OFF” (0) position, see fig. 4.0-D.
C
heck all connections on water leakage.
Close the ball valves and check the mesh
filter by unscrewing the base of it to see that
it is not clogged with dirt and debris.
Open the ball valves again and turn the
mains switch back in the “ON” position.
The flame effect is too low
on the highest setting.
The transducers and/or air
filter are dirty.
Call for maintenance.
The flame effect is too
high and there is too much
smoke.
The extractor fan doesn’t work
anymore.
Check if the fan, mounted at the top right
inside the fire, is running.