9 <
<
<
<
3
Installation requirements
3.1
Appliance
This appliance may not be installed in a
chlorine-containing environment. (Pools
etc.).
This appliance must be built into an
existing or new false chimney.
For appliances with flexible gas pipes, the
control unit (fig. 1.0) is placed on the right
side of the crate for transport reasons.
Detach and mount it together with the
remote access door in as low as possible
position in the false chimney.
(To prevent damage to cables and pipes
during transport, they are bound together
by tie wraps. Remove these to ensure
proper operation of the appliance.)
If desired, a 2 meter pipe set is available
(article number 20900715).
3.2
False chimney
The false chimney should be of non-
combustible material.
The space above the fire should always be
ventilated using grids with minimal free
passage of 200cm² per grid.
The false chimney construction should not
rest on the build-in frame of the fireplace.
3.3
Discharge and outlet requirements
First, carry out a flue calculation (see chapter 11)
and place the right flue restrictor before installing
the outlet! (Generally a 30mm flue restrictor is
installed).
For supply and discharge always use the
prescribed and to be supplied Faber flue
materials. Please contact Glen Dimplex
Benelux B.V.. Only with use of these
materials Faber can guarantee proper
performance.
The distance to combustible materials
must be min. 50mm, calculated from
outside of the flue material (EN 1856-1
T600 N1 D VM – L20040 O(50)).
Outlets (fig. 1.2)
The balanced flue pipe for combined air supply and
discharge can use a wall terminal or a roof
terminal. Verify that the desired outlet meets the
local regulations regarding pollution and
ventilation openings.
Please note!
For proper functioning, the outlet must at
least be 0,5m away from:
Corners of the building;
Roof overhangs and balconies;
Roof edges (with the exception of the
ridge edge, see chapter 15).
C11, outlet via facade
Through a wall or façade, use a Faber wall outlet.
Depending on the flue calculation this can be
100/150mm or 130/200mm.
C31, outlet via roof
For a (flat) roof, use a Faber roof outlet with a
diameter of 100/150mm.
C91, existing chimney
For an existing chimney, use a Faber chimney
outlet with a diameter of 100/150mm.
In this case the existing chimney acts as air inlet an
inserted flexible stainless steel pipe discharges the
flue gas. The top (Faber chimney cover plate) and
the bottom (Faber chimney connection set) should
be airtight.
Depending on the calculated flue diameter, you
must use a flexible stainless steel pipe of
Ø100mm (article number AJ005503) or Ø130mm
(article number AJ005603) as specified by Faber.
For this, contact Glen Dimplex Benelux B.V.
Please note!
The minimum chimney diameter for a
130mm flexible stainless steel pipe must
be 200x200mm and for a 100mm flexible
stainless steel pipe and 150x150mm.
Don’t connect more than one fire at the
existing chimney.
The chimney must be in good condition:
o
No leakage;
o
Well cleaned.
For more information about the connections to
existing chimney ducts, please request the
installation instructions “Chimney Connection Set”.
4
Preparation and installation
instructions
4.1
Gas connection
The gas connection must comply with the
applicable local standards.
Please note!
Provide a flexible gas connection with at
least 0,5m extra length, so that the
control unit can be removed for
installation and service!
Calculate the gas pipe so that no
pressure drop occurs.
Summary of Contents for Duet L Smart
Page 1: ...Installation manual Duet M Smart Duet L Smart ENG 40011620 2010 ...
Page 2: ...Installation manual Duet M L Smart 1 ...
Page 3: ...Installation manual Duet M L Smart 2 ...
Page 4: ...Installation manual Duet M L Smart 3 1 0 1 1 1 2 1 3a 1 3b ...
Page 5: ...Installation manual Duet M L Smart 4 1 4 1 5 1 6 1 7 1 8 Y X ...
Page 6: ...Installation manual Duet M L Smart 5 2 0a 2 0b 2 0c 2 1 3 0 3 1 3 2 4 0 A B A Q R S T E E B ...
Page 7: ...Installation manual Duet M L Smart 6 4 1 4 2 4 3 4 4 ...
Page 8: ...Installation manual Duet M L Smart 7 ...
Page 18: ...Installation manual Duet M L Smart 17 12 Examples flue materials ...
Page 24: ...Installation manual Duet M L Smart 23 16 Troubleshooting guide ...
Page 25: ...Installation manual Duet M L Smart 24 ...
Page 27: ...Installation manual Duet M L Smart 26 17 2 Duet M Smart left M with insert strip ...
Page 28: ...Installation manual Duet M L Smart 27 17 3 Duet M Smart right with cover strip ...
Page 29: ...Installation manual Duet M L Smart 28 17 4 Duet M Smart right with insert strip ...
Page 30: ...Installation manual Duet M L Smart 29 17 5 Duet L Smart left with cover strip ...
Page 31: ...Installation manual Duet M L Smart 30 17 6 Duet L Smart left with cover strip ...
Page 32: ...Installation manual Duet M L Smart 31 17 7 Duet L Smart right with cover strip ...
Page 33: ...Installation manual Duet M L Smart 32 17 8 Duet L Smart right with insert strip ...
Page 34: ...Installation manual Duet M L Smart 33 17 9 Wall bracket Duet M Smart article number A9322596 ...
Page 35: ...Installation manual Duet M L Smart 34 17 10 Wall bracket Duet L Smart article number A9322696 ...
Page 36: ...Installation manual Duet M L Smart 35 17 11 Remote access door article number A9299463 ...
Page 37: ...Installation manual Duet M L Smart 36 17 12 Ventilation grid article number A9296400 ...
Page 38: ...Installation manual Duet M L Smart 37 17 13 Adjustable feet Article number A9319696 ...
Page 40: ...Installation manual Duet M L Smart 39 18 2 Log set Duet L Smart ...
Page 41: ...Installation manual Duet M L Smart 40 ...
Page 42: ...Installation manual Duet M L Smart 41 ...