Page 1: ...Concept l 450 40011643 1550 Concept l 450 ENG ...

Page 2: ...I n s t a l l a t i o n I n s t r u c t i o n s 2 1 1 1 2 ...

Page 3: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 1 6 1 3 1 4 1 5 ...

Page 4: ...I n s t a l l a t i o n I n s t r u c t i o n s 4 1 7 2 1 2 2 3 1 B A 2 1 ...

Page 5: ...I n s t a l l a t i o n I n s t r u c t i o n s 5 4 1 3 2 3 3 ...

Page 6: ...e obstructed and particular care must be taken when placing the logs pebbles or stones which are supplied with the fire The unit is for atmosphere and heating purposes This means that all surfaces including the glass can be very hot over 100 C exceptions to this are the bottom of the fire and the control elements Do not place any combustible materials within 0 5m of the radiation area of the fire ...

Page 7: ...maging of the casing Removing the glass frame goes in reverse order 5 Removing the glass Remove the glass frame See par 4 8 Place the suction cup onto the glass Fig 3 1 and 3 3 Remove the glass clamps by using a screw driver Fig 3 2 Move the glass forwards To replace the glass repeat the process in reverse order Note Remove the fingerprints from the glass these will burn in and cannot be removed a...

Page 8: ... 1 air supply 2 flue gas The ratio CO2 and CO must not be greater than 1 100 Example CO2 is 4 and CO is 400ppm measured at the highest point If the ratio is greater than 1 100 or exhaust gases are measured in the supply air then also check above points 8 Instructions for client Recommend that the unit should be checked annually by a qualified specialist to ensure the safe use and to guarantee a lo...

Page 9: ...0 127 0 164 at 15º C and 1013 mbar gr h 320 310 Burner pressure at full mark mbar 10 24 8 31 6 Injector main burner mm 1 9 1 1 1 1 Reduced input restraint mm 1 1 0 85 0 85 Pilot flame OP NG9030 OP LPG9222 OP LPG9222 Code pilot flame injector Diameter outlet inlet mm 100 150 100 150 100 150 Gas controle valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electrical connection V 230 230 230 Batteries re...

Page 10: ...lets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof terminal Only for existing Chimney connection Extension pipe over roof 12 Terminal position Please note These rules apply only for the proper functioning of the unit for ventilation and environmental protection y...

Page 11: ...ut of a small piece from the sparking plug Tie wraps removed Cable is free from any metal parts 4x 1 5V AA Alkaline Thermocouple circuit is interrupted check 8 wire cable from receiver to the gas valve If the wire on the bottom of the gas valve is not broken or stuck and makes a ground contact Motor gas valve doesn t work Micro switch on gas valve doesn t work 3 short beep s 1 long beep Faulty sol...

Page 12: ...lot burner is leaking Gasket between burner unit is leaking Glass seal is leaking Flue parts aren t 100 connected check flue system Replace batteries in the receiver Check the distance from thermocouple to pilot flame Measure the mvolts over the thermocouple required min 4mvolts over black and ground contact Flame stays blue lift from the burner and fire switch of Check flue calculation horizontal...

Page 13: ...aulty parts RESET the receiver Gas vlave broken poor or loose contact Short circuit in wiring Install a ground cable from the gas valve to the appliance Optional Step burner function can be turned ON and OFF only with remote RESET the receiver Check the wiring from solenoid valve to receiver Faulty solenoid valve Faulty receiver Repaire the wiring Replace solenoid valve Replace receiver ...

Page 14: ...1 4 I n s t a l l a t i o n I n s t r u c t i o n s 14 Dimensional drawings 14 1 Concept I 450 ...

Page 15: ...1 5 I n s t a l l a t i o n I n s t r u c t i o n s 14 2 Position gasvalve and wall terminal ...

Page 16: ...1 6 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen Dealerinfo ...