RECIRCULATION VERSION AIR OUTLET 

To install the Recirculation Version of the hood, the optional Ac-
tivated charcoal cartridge kit must be purchased. 
•  Screw the filter cover onto the air outlet, using four screws 

12c

 

(2.9 x 12.5). 

•  Fix the directional grille 

8

 on the recirculation air outlet using 

the 2 screws 

12d

 (2,9 x 9,5) provided.

 

 

16

12c

12d

8

ELECTRICAL CONNECTION 

•  Connect the hood to the mains through a two-pole switch hav-

ing a contact gap of at least 3 mm. 

•  Remove the grease filters (see paragraph Maintenance) being 

sure that the connector of the feeding cable is correctly inserted 
in the socket placed on the side of the fan. 

 

Flue assembly 

The chimney can only be installed with exhausting hood 
•  Fasten the angle iron 

15

 to the hood canopy using the screws 

12d 

(2,9 x 9,5)  provided. 

Upper exhaust flue

 

•  Slightly widen the two sides of the upper flue and hook them 

behind the brackets 

7.2.1

, making sure that they are well 

seated. 

•  Secure the sides to the brackets using the 4 screws 

12c

 (2,9 x 

6,5) supplied. 

Lower exhaust flue

 

•  Slightly widen the two sides of the flue and hook them be-

tween the upper flue and the wall, making sure that they are 
well seated. 

•  Fix the lower part laterally to the hood body using the 2 screws 

12c

 (2,9 x 6,5) supplied.

 

12c

2.1

2.2

2

7.2.1

12c

Summary of Contents for COCKTAIL

Page 1: ...INSTRUCTIONS MANUAL EN COCKTAIL...

Page 2: ...der to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Nev...

Page 3: ...e 9 1 Flange optional 15 1 Angle iron optional 16 1 Filter cover Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets optional 11 6 Wall Plugs 4 optional 11a 2 Wall Plugs SB...

Page 4: ...EN 5 5 Dimensions Min 500mm Min 500mm...

Page 5: ...other side checking that the two marks are levelled Drill at the marked points 1 using a 12 mm drill bit Drill at the marked points 2 using a 8 mm drill bit Insert the bracket plugs 11a into the holes...

Page 6: ...r to level the hood body itself Fasten the safety screw 12a Close the doors the door again 12a Vr 11a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood...

Page 7: ...he connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Flue assembly The chimney can only be installed with exhausting hood Fasten the angle iron 15 to the...

Page 8: ...on is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 seconds to activate In tensive speed which is timed to...

Page 9: ...ly for particularly heavy usage and can be washed in a dishwasher Pull the comfort panels to open them Remove the filters one by one pushing them towards the back side of the hood unit and simultaneou...

Page 10: ...ilters Remove the saturated activated charcoal filter as shown A Fit the new filters B Replace the metal grease filters Close the comfort panels A B Lighting LIGHT REPLACEMENT 20 W halogen light Remov...

Page 11: ...estique dans le but d liminer les odeurs de la cuisine Nejamaisutiliserabusivementlahotte Nepaslaisserlesflammeslibres forteintensit quandlahotteestenservice Toujours r gler les flammes de mani re vit...

Page 12: ...ul Arsenija arnojevi a 66 BEOLEKS MK j 02 322 75 80 2 043 412 551 047 242 885 56 044 337 919 034 320 551 65 SKOLEKS 02 963 33 20 963 33 80 49 032 633 778 30 052 504 634 277 056 841 475 77 082 872 717...

Reviews: