Faber Axia Isola Island Mount Canopy Rangehood Installation Instructions Manual Download Page 2

Version 3/08 - Page 2

VENTING   REQUIREMENTS

Determine which venting method is best for your application.  

Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should 

be kept to a minimum to provide efficient performance.  The 

size of the ductwork should be uniform.  Do not install two el-

bows together.  Use duct tape to seal all joints in the ductwork 

system.  Use caulking to seal exterior wall or floor opening 

around the cap.

Flexible ductwork is not recommended.  Flexible ductwork 

creates  back  pressure  and  air  turbulence  that  greatly 

reduces performance.

Make sure there is proper clearance within the wall or floor for 

exhaust duct before making cutouts.  Do not cut a joist or stud 

unless absolutely necessary.  If a joist or stud must be cut, then 

a supporting frame must be constructed. 

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO 

TO PAGE 4.

WARNING - To Reduce The Risk Of Fire, Use Only Metal 

Ductwork.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a 

separate 15 amp fused circuit.  A time-delay fuse or circuit 

breaker is recommended.  The fuse must be sized per local 

codes in accordance with the electrical rating of this unit as 

specified on the serial/rating plate located inside the unit near the 

field wiring compartment.  THIS UNIT MUST BE CONNECTED 

WITH COPPER WIRE ONLY.  Wire sizes must conform to the 

requirements of the National Electrical Code, ANSI/NFPA 70 

- latest edition, and all local codes and ordinances.  Wire size 

and connections must conform with the rating of the appliance.  

Copies of the standard listed above may be obtained from: 

 

National Fire Protection Association

 

Batterymarch Park

 

Quincy, Massachusetts  02269

• Venting system MUST terminate outside the 

home.

• DO NOT terminate the ductwork in an attic or 

other enclosed space.

• DO NOT use 4" laundry-type wall caps.

• Flexible-type ductwork is not recommended.

• DO NOT obstruct the flow of combustion and 

ventilation air.

• Failure to follow venting requirements may result 

in a  fire.

This appliance should be connected directly to the fused discon-

nect (or circuit breaker) through flexible, armored or nonmetallic 

sheathed copper cable.  Allow some slack in the cable so the 

appliance can be moved if servicing is ever necessary.  A UL 

Listed, 1/2" conduit connector must be provided at each end 

of the power supply cable (at the appliance and at the junction 

box).

When making the electrical connection, cut a 1   1/4" hole in the 

wall.  A hole cut through wood must be sanded until smooth.  A 

hole through metal must have a grommet. 

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC 

SHOCK, do not use this fan with any solid-state speed 

control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI

-

CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:  Use this unit only in the manner intended 

by the manufacturer.  If you have any questions, contact 

the manufacturer.

Before  servicing  or  cleaning  unit,  switch  power  off  at 

service panel and lock the service disconnecting means 

to  prevent  power  from  being  switched  on  accidentally.  

When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a tag, 

to the service panel.

CAUTION: For General Ventilating Use Only.  Do Not Use To 

Exhaust Hazardous  or  Explosive Materials and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI

-

CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING: Installation Work And Electrical Wiring Must 

Be Done By Qualified Person(s) In Accordance With All 

Applicable  Codes  And  Standards,  Including  Fire-Rated 

Construction.  

Sufficient air is needed for proper combustion and exhaust

-

ing of gases through the flue (chimney) of fuel burning 

equipment  to  prevent  backdrafting.    Follow  the  heating 

equipment manufacturer's guideline and safety standards 

such as those published by the National Fire Protection 

Association (NFPA), and the American Society for Heating, 

Refrigeration and Air Conditioning Engineers (ASHRAE), 

and the local code authorities.

When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.

   WARNING

• Electrical ground is required on this rangehood.

• If cold water pipe is interrupted by plastic, 

nonmetallic gaskets or other materials, DO NOT 

use for grounding.

• DO NOT ground to a gas pipe.

• DO NOT have a fuse in the neutral or grounding 

circuit.  A fuse in the neutral or grounding circuit 

could result in electrical shock.

• Check with a qualified electrician if you are in doubt 

as to whether the rangehood is properly grounded. 

• Failure to follow electrical requirements may result 

in a fire.   

   WARNING

For residential use only.

!

!

Cold Weather installations

An additional back draft damper should be installed to minimize 

backward cold air flow and a nonmetallic thermal break should 

be installed to minimize conduction of outside temperatures 

as part of the vent system. The damper should be on the cold 

air side of the thermal break. The break should be as close as 

possible to where the vent system enters the heated portion 

of the house.

Summary of Contents for Axia Isola Island Mount Canopy Rangehood

Page 1: ...E DE CUISSON a Ne jamais laisser un l ment de la table de cuisson fonctionner sans surveillance la puissance de chauffage maximale un renversement d bordement de mati re graisseuse pourrait provoquer...

Page 2: ...a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any...

Page 3: ...ssociation Am ricaine d Ing nieurs de Chauffage Frigorifaction et Air Climatis ainsi que les codes municipaux En per ant un mur veillez ne pas perforer un autre fil lectrique Une ventilateur vacuation...

Page 4: ...packaging the entire chimney section of the hood is shipped assembled It must be disassembled completely for installation Disassemble packaged chimney components by sliding apart the chimney covers B...

Page 5: ...he hood and the cooktop distance x in FIGURE 4 DUCTED INSTALLATION DIMENSIONS vented to the outside PLAN THE INSTALLATION This rangehood can be installed as either ducted or ductless When installed du...

Page 6: ...distance x in FIGURE 5 upper chimney cover ductless lower chimney cover canopy cabinet base x distancefromhoodtocooktop varies depending on installation min 24 suggested max 30 also consult cooktop m...

Page 7: ...REXTENSION HORIZONTAL D into the DIVERTER C 1 The UPPER CHIMNEY COVER C in FIGURE 9 attaches using two screws provided G in FIGURE 9 Slide up and attach the UPPER CHIMNEY COVER 2 Attach the duct work...

Page 8: ...urn knob to the right to lock the filter into place FIGURE 14 8 Turn the power supply on Turn on blower and lights If the rangehood does not operate check that the circuit breaker is not tripped or th...

Page 9: ...sefiltersshouldbecleanedfrequentlyin hot detergent solution or washed in the dishwasher Stainless steelcleanershouldbeusedonstainlessrangehoods Abrasives and scouring agents can scratch stainless stee...

Page 10: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than nor...

Page 11: ...ures NE PAS RETIRER LE PLASTIQUE PROTECTEUR Ce plastique emp che tout dommage pouvant survenir pendant l installation S parer le COUVERCLE CHEMIN E SUP RIEURE C de la FIGURE 1 et le COUVERCLE CHEMIN E...

Page 12: ...po min 7 pi 7 5 8 po max 8 pi 6 5 8 po x 24 po min 7 pi 5 5 8 po max 8 pi 4 5 8 po PLAN DE L INSTALLATION Cette hotte peut tre install e avec ou sans conduit Lorsque install sans conduit la ventilati...

Page 13: ...po x 26 po min 8 pi 5 8 po max 8 pi 6 5 8 po x 24 po min 7 pi 10 5 8 po max 8 pi 4 5 8 po 20 po 2 5 8 po 3 3 4 dimensions d installatioN SANS CONDUIT La chemin e Axia Isola sans conduit estr glablepo...

Page 14: ...E D ALIMENTATION Retirer le couvercle du compartiment de c blage NE PAS mettreencircuittantquel installationn estpascompl t e Brancher le c ble d alimentation sur la hotte Relier le fil blanc du c ble...

Page 15: ...rsiledisjoncteurn estpasd clench ousilefusiblen est pas grill Si l appareil ne fonctionne toujours pas d brancher l alimentation et v rifier si les connexions ont t effectu es correctement 7 Installer...

Page 16: ...de d tergent ou mettre au lave vaisselle Utiliser un nettoyant pour l acier inoxydable sur les hottes en acier inoxydable Ne pas employer de produits abrasifs ou de poudre r curer qui peuvent endommag...

Page 17: ...parer les fusibles de votre maison ou pour corriger votre c blage ou votre syst me de plomberie 2 Les appels de service pour remplacer ou r parer les ampoules les fusibles ou les filtres de votre hott...

Reviews: