L
10 <
<
<
<
3.4
terminals
The flue outlet can end on an external wall or a roof . Check whether the outlet desired
by you complies with local requirements concerning good function and ventilation
systems .
For a proper functioning the terminal should be at least 0.5 m. away from:
Corners of the building.
Roof overhangs and balconies.
Eaves (with the exception of the roof ridge).
4
Preparation and Installation instructions
4.1
Gas connection
The gas connection must comply with locally valid standards.
We advise Pipe work from the meter to the appliance must be of adequate size., with near
the appliance a gas control tap that should always be accessible. Place the gas connection
in such a way that this is easily accessible, and that before service, the burner unit can be
dismounted at all times.
4.2
Electric connection
If an adapter is used for the power supply, then a wall socket 230VAC – 50Hz must be
mounted in the close neighbourhood of the hearth.
4.3
Preparation of the appliance
Remove the packaging of the appliance . Make sure the gas pipes underneath the
appliance are not damaged.
Clear a safe space to store the frame and the glass.
Remove the frame , (if necessary) and the glass and take the separately wrapped
parts out of the appliance
transport support plate C (see fig. 1.3 ) should not be removed until after the
appliance has been put in position.
Prepare the gas connection to the gas control valve.
Summary of Contents for Aspect L RD
Page 1: ...Aspect L RD Installation guide ENG ENG 30cm 4001941 1021 ...
Page 2: ...L 1 1 1 1 2 1 3 1 4 A D B C 1 ...
Page 3: ...L 2 1 5 1 6 1 7 1 8 E E A ...
Page 4: ...L 3 2 1 2 2 2 3 2 4 ...
Page 5: ...L 4 2 5 2 6 2 7 2 8 2 9 3 0 1 2 ...
Page 6: ...L 5 3 1 3 2 3 3 ...
Page 22: ...L 14 Dimensions of the appliance 21 ...
Page 23: ...L 22 15 Dimensions ventilation grills ...
Page 24: ...23 L 16 Dimensions service Hatch ...
Page 25: ......