FABER-COM CLG-SL Quick Start Manual Download Page 4

MAP2 / MAP2L

CLG-SL

FABER-COM srl - Via Romana 36/1 - 42028 Poviglio (RE) - Italy  Tel. +39-0522-960428   Fax. +39-0522-969644 - www.fabercom.it

\Prodotti\Limitatore CLG\PCLG-LxE[CLG-SL- Barra LED]\Documenti\SM#Limitatore CLG-SL_v102 - 19/04/2017

COM

FABER -  

PRG2-DEC

NEXT

NEXT

PREV

PREV

COM

FABER -  

RS-232 Adapter

CLG

Serial cable

Ordering code:  

PISPM

programming
connector

Page 4 / 6

Setting parameters by final user

Hardware key to increase the load limit threshold

The load limiter's thresholds are programmed using an external, little, 4 buttons, 
keyboard. The keyboard is an optional. Its name is "PRG-CLG". When it is 
connected the green led blinks four times in a second.

The PRG2 (either CLG version or DEC version) can be used even to increase 
the load limit threshold up to 125%, for a brief period of time. 

In order to increase the limit: when you connect the PRG2, the "+" button has to 
be pressed within 5 seconds then kept pressed till the green led blinking will 
becomes slower. 

In most cases, CLG load limiter doesn't need to be connected to PC:

- thresholds are programmed by means of PRG 2 keyboard

- fault analysis is done by means of the green LED placed near connector

It is possible to connect CLG card to PC with serial port using the special serial adapter AISM (code: PISPM) and 
free SepSim Windows® program.

PC connection is required in the following cases:

- to set whole the load limiter's parameters 

- upload/download the working configuration

- to monitor some working parameters when fault occurs 

- to update the firmware

PC connection

Summary of Contents for CLG-SL

Page 1: ...witch supply A6 not used A7 DV input A8 Emergency input B1 RX serial comm B2 V PRG2 supply B3 ground for 90 signal B4 ELV1 signal B5 ELV1 ground B6 input TRANSD 1 P B7 input DECREMENT B8 Emergency output C1 TX serial comm C2 PRG2 ground signal C3 ground for 100 signal C4 not used C5 not used C6 input RESET C7 not used C8 GND Pinout FCI connector 24 ways CLG SL Load limiter is an electronic device ...

Page 2: ...inks following a particular sequence related to the fault reasons look at the last page for a detailed blinking sequence meaning Also it is present a LED bargraph to show the load percentage in real time compared to the maximum load When the load exceedes the 100 of the limit red LED of the bargraph blinks Leds placed into the emergency button box red colour and yellow colour are lighted in the fo...

Page 3: ...r when its value is low a reduced pressure threshold is used INCREASE THRESHOLD optional that input has to be coupled with first boom descent manoeuvre When input value goes high the load limit threshold is increased by a fixed value specified in a configuration parameter in order to offset the pressure increase due to overcenter valves which operate during this manoeuvre PRESSURE transducer input...

Page 4: ...2 either CLG version or DEC version can be used even to increase the load limit threshold up to 125 for a brief period of time In order to increase the limit when you connect the PRG2 the button has to be pressed within 5 seconds then kept pressed till the green led blinking will becomes slower In most cases CLG load limiter doesn t need to be connected to PC thresholds are programmed by means of ...

Page 5: ...S with LED 90 and 100 wire 0 5mm L 30 cm to connect the remote control DV hidden under the conduit Programming keyboard PRG2 CLG 2x0 75 L 5 0m protection conduit øext 11mm RESET LIMIT REDUCTION 2 Code PASMLMxxx Control unit CLG cabling Code PCLG LyE Only control unit Code A1003720022 400bar Pressure transducer Code A1003720021 250bar Pressure transducer Code PPRG2MC programming keyboard Ordering c...

Page 6: ...des the maximum working limit Input from transducer 1 is lower than minimum working value Input from transducer 2 is lower than minimum working value The current value on the valve 1 is outside the normal working range The current value on the valve 2 is outside the normal working range The input transducer 1 is in protection mode The input transducer 2 is in protection mode Relay broken because o...

Reviews: