Fabdec Dari-Kool 720012 Installation And Operation Manual Download Page 7

Page 7

Operation

The control cabinet is operated at three levels:

Working level 

... for everyday operation by the end user.

When cooling mode is active, the milk temperature as 
currently measured is permanently displayed.

The working level also contains the functions:

!

start cooling mode

!

Intermitted stirring during cooling mode (duration 
depending on pre-setting). See section "Intermediate 
stirring options during cooling" on Page 13.

!

Start permanent stirring

!

Switch of

!

Switch over target temperatures 4° / 8° (when activ)

!

Display and change of target temperatures 4° / 8°Note: 
The changing of targetTemperatures is only possible, 
when in programming level the parameter button lock 
[C99] is set to '0'.

Programming level

This is the level at which the regulatory parameters are set.

Setting is more complex and possible only using specific 
combinations of buttons so as to prevent accidental chan-
ges to settings.

Configuration level

This is the level at which the basic functions of the regulator 
are set.

As subsequent interventions by the end user (after the 
parameters have been set) can result in dangerous chan-
ges to functions which might not be immediately obvious, 
access to the configuration level is even more complex.

Operation overview

!

The milk is cooled to the selected target temperature (4° 
or 8°).   (The adjusted target temperature is displayed by 
LED 4° or 8°).   The stirrer runs constantly at this stage.

!

Once the target temperature has been reached the 
compressor switches off.

!

The stirrer switches off after the programmed afterstir-
ring time.

!

During refrigeration pauses, the stirrer switches on for 
the duration of the afterstirring time to ensure an even 
temperature throughout the milk. This will be repeaded 
periodically.

!

Should the milk temperature exceed the selected target 
temperature (4° or 8°) by the hysteresis value, the 
compressor and stirrer are automatically switched on 
again. 

T2

T1

Hysteresis
for T2

Hysteresis
for T1

Target
temperature

Target
temperature

°C

STOP

SET

4°/8°

Working

level

Programming

level

Configuration

level

for every day operation

for setting the regulator parameters

for setting the basic functions

Summary of Contents for Dari-Kool 720012

Page 1: ...2016 Installation and Operation Manual Control for milk cooling tanks COMPACT KOOL...

Page 2: ...ion Page 9 Programming level operation Page 10 Configuration level operation Page 11 Intermediate stirring options during cooling Page 13 Continuous stirring in OFF mode Page 13 Setting the actual val...

Page 3: ...pressing a button Cooling mode Press the 4 8 button the compressor and agitator operate automati cally In between cooling periods agitator and compressor LEDs off intermediate stirring can be activat...

Page 4: ...ce must not be installed in potentially explosive atmospheres The control cabinet for milk cooling tanks fulfils the EC requirements for electromagnetic compatibility EMC and the Low Voltage Directive...

Page 5: ...it is necessary to shorten or lengthen the sensor cable on installation or if a sensor other than the one supplied is to be fitted the actual value correction parameter must be adjusted accordingly S...

Page 6: ...itching contactor and motor protection switch 2 make contacts 16A AC 1 250 V 13 mm LED Display 3 digits 0 1 C 1 0 C two step controller 50 150 C 0 1 to 99 9 K free adjustable standard adjusting 0 7 K...

Page 7: ...of the regulator are set As subsequent interventions by the end user after the parameters have been set can result in dangerous chan ges to functions which might not be immediately obvious access to t...

Page 8: ...kly Release button SET To store the changed parameter in the memory first release the arrow button and then button SET Switching back to working level possible from any parameter Press button Arrow UP...

Page 9: ...ds or downwards Button Agitator in cooling mode press for appr 1 sec SHORT intermediate stirring press for appr 3 sec LONG intermediate stirringSee also the section describing the intermediate stirrin...

Page 10: ...n after being turned off Parameter C50 Duration of SHORT intermittent stirring Duration min of stirring after short pressing of the intermittent stirring button Parameter C51 Duration of LONG intermit...

Page 11: ...he hysteresis is always upwards In the case of heating contacts it is below the target temperature cooling or heating contact is set at configuration level In the symmetrical hysteresis mode the value...

Page 12: ...g of minimum pause time for compressor relay contacts K1 in order to prevent repeated switching on and off Range 0 0 999 seconds Parameter P80 Switch from target temperatur T1 to T2 Setting of funktio...

Page 13: ...diately otherwise Intermediate stirring LONG will be activated Intermediate stirring LONG Press agitator button for approx 3 secs until Lon appears in the display The duration of SHORT or LONG stirrin...

Page 14: ...C91 Actual value correction must then be adjusted at programming level Memory fault Faulty regulator Remove the regulator and send it for repair Measurement range exceeded The maximum measurement ran...

Page 15: ...However in practice this is possible only with difficulty as even a normal contactor without interference suppres sion produces interference pulses of up to 3 0 kV For this reason we recommend that t...

Page 16: ...example be limited by using self induction diodes varistors or suppresser diodes The diagram on the left shows one possibility using a self induction diode AC voltage In the case of a c voltage interf...

Page 17: ...he use of zero voltage switches is also recommended The suggestions made represent only a few of the possible ways of protecting a microprocessor controlled regulator system from interfer ence The sug...

Page 18: ...0 1691 627200 Fax 44 0 1691 627222 Email sales fabdec com Fabdec GmbH Gerhardstrasse 5 45892 Gelsenkirchen Germany Tel 49 0 209 700 900 Fax 49 0 209 70090 20 Email germany fabdec com Fabdec LLC Octobe...

Reviews: