SYMPTOMS
POSSIBLE CAUSES
CORRECTIVE ACTION
Red LED flashing quickly after an assisted
setup.
The sensor ‘sees’ the door movement and
can not finish its setup.
Adjust the position of the IR curtains.
Orange LED permanently ON.
The sensor encounters signal saturation.
Use the wide-field prism and/or slightly increase the IR curtains angle
(turning the screw counterclockwise). Launch an assisted setup.
Orange LED flashes
The sensor signals an internal fault.
Cut and restore the power supply.
If the orange LED lights up again, replace faulty sensor.
Red LED ON
The sensor detects a presence.
Wait the time set in “maximum duration of presence detection” setting or
launch an assisted setup (with right push button).
Unwanted presence detection
The sensor is not placed properly
and/or the front face is not properly fixed.
Fasten the sensor firmly and/or
check whether the front face prism is placed into the foreseen slides
(see section 6) and not in the sensor cover.
Supply voltage
: 12V (– 5%) to 24V (+10%) AC/DC
Mains frequency
: 50 - 60 Hz
Power consumption
: < 3 W
Mounting height
: 1.8 m to 3 m
3-color LED
: RED (presence detection) – GREEN (motion detection) – ORANGE (signal saturation, error)
Temperature range
: -25°C to +55°C
Degree of protection
: IP54
Dimensions
: 262 mm (L) x 55 mm (H) x 44 mm (D)
Weight
: 250 g
Housing material
: ABS + LURAN S
Minimum length of cable
:
±
2.6 m
MOTION SENSOR
PRESENCE SENSOR
Detection mode
Motion - Bidirectional
Minimum detection speed: 5 cm/s (measured in sensor
axis)
Presence
Typical response time: < 128ms (max. 500 ms)
Technology
Microwave and microprocessor
Transmitter frequency:
24.175 GHz
Transmitter radiated power:
< 20 dBm EIRP
Transmitter power density:
< 5 mW/cm²
Focused active infrared
Spot diameter (standard): 0.1m max
Number of spots:
24
(12 with narrow field prism)
Number of curtains:
2
Detection field
Width
Depth
Wide
4 m
2 m
Narrow
2 m
2,5 m
Width
Depth
Wide
2 m
0,35 m
Narrow
1 m
0,35 m
Angle
From 15° to 50° in elevation (adjustable)
From - 4° to + 4° (adjustable)
Output specification
Relay (free of potential contact):
Max. contact voltage: 42V AC/ DC
Max. contact current: 1A (resistive)
Max. switching power: 30W (DC) / 60VA (AC)
Relay (free of potential contact):
Max. contact voltage: 42V AC/ DC
Max. contact current: 1A (resistive)
Max. switching power: 30W (DC) / 60VA (AC)
Output holdtime
0.5s
0.1/1s
Max. presence
detection time
30s (standard)
10s + curtain 2 in motion detection only (during 2h in case of disturbances)
Number of
reference pictures
2
Sensing field dimensions given at 2.2m mounting height.
Specifications are subject to changes without prior notice.
XAC
5 Technical
Specifications
6 Accessories
(sold individually)
42.
0677 /
V3 – 01.
08
785183
4 Troubleshooting