background image

 

1/4 

 

  XMA 

USER'S GUIDE

 

 

COMBINED BIDIRECTIONAL OPENING AND SAFETY SENSOR  

WITHOUT ANY MONITORING FUNCTION

 

 

 

 
 
 

 

 

 

 

Cover  
 
 
 
Push-Buttons 

 Radar motion sensor 

 

 Radar Antenna 

 

 Radar tilt angle indication  

45° 
30° 
15° 

 

IR-Presence sensor 

 

 
 

IR-Prism 

 

 
 
Main Connector 
 
 

IR curtain adjustment screw 

 

 

 
 

 

 

 

 

 

 

 

  

 

 

 

 

 

LED turns on 

  LED flashing slowly    LED flashing quickly

 

Motion detection 

  Presence detection 

 

Tip 

 

LED display during normal function 

 

 

GREEN LED  

Motion detection 

 

 

 

 

RED LED  

Presence detection  

 

 

 

 

ORANGE LED 

See chapter 4: Troubleshooting 

 

 

 

Tips

 

 

 

 

 

 

 

 

 

 

Avoid touching electronical 

parts! 

  Avoid touching optical parts!   

Make sure the operator 

cover is fixed properly and 

electrically earthed. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Avoid vibrations!!!

 

 

Do not cover the sensor! 

 

Avoid moving objects in 

proximity to the sensor! 

 

Avoid discharge lamps and 

fluorescent lighting in proximity 

of the detection field! 

 

Avoid highly reflective 

objects in the infrared field! 

 
 

 

 

 

 

 

1 Description 

3 Installation 

2  Symbols and LED 

Summary of Contents for XMA

Page 1: ...on Tip LED display during normal function GREEN LED Motion detection RED LED Presence detection ORANGE LED See chapter 4 Troubleshooting 1 Tips Avoid touching electronical parts Avoid touching optical parts Make sure the operator cover is fixed properly and electrically earthed Avoid vibrations Do not cover the sensor Avoid moving objects in proximity to the sensor Avoid discharge lamps and fluore...

Page 2: ...ensor 3 Wiring the sensor To ensure good water protection place the cable as shown above 4 Radar motion sensing field width Sensitivity 9 Sensitivity 9 Touching the antenna patches while exchanging will not cause any damage 5 Radar motion sensing field depth 15 30 45 30 45 15 0 2 1 0 1 2 1 2 3 1 2 3 15 30 45 Sensitivity 9 2 1 0 1 2 1 2 3 1 2 3 15 45 30 4 4 Sensitivity 9 ...

Page 3: ...rt setup Cut and restore power Recommended after adjustments by push buttons The sensor takes a new reference picture Assisted setup Press and hold the right push button until the LED flashes RED GREEN Recommended after first installation or mechanical adjustments of the IR module The sensor performs a door opening and closing cycle to check the influence of the door leaves on the safety curtain L...

Page 4: ...ight 250 g Housing material ABS LURAN S Minimum length of cable 2 6 m MOTION SENSOR PRESENCE SENSOR Detection mode Motion Bidirectional Minimum detection speed 5 cm s measured in sensor axis Presence Typical response time 128ms max 500 ms Technology Microwave and microprocessor Transmitter frequency 24 175 GHz Transmitter radiated power 20 dBm EIRP Transmitter power density 5 mW cm Focused active ...