Avoid vibrations!!!

 

  Do not cover the sensor! 

 

Avoid moving objects in 

proximity of the sensor! 

 

Avoid HF lamps and 

fluorescent lighting in 

proximity of the sensor! 

 Do not remove the protection 

which avoids contact with the 

electronical parts! 

 
 

 
 

 

 

 

 

 
 

 

Technology                     

: microwave and microprocessor 

Transmitter frequency    

: 24.175 GHz 

Transmitter radiated power 

: <20 dBm EIRP 

Transmitter power density 

: < 5 mW/cm² 

Mounting height 

: from 1.8 m to 3 m 

Tilt angles 

: 0° to 90° vertical and -30° to + 30° lateral 

Detection area  (mounting height = 2.2 m) 

: 4m (W) x 2m (D) 

Detection mode 

: motion 

Minimum speed 

: 5 cm/s (measured in the sensor axis) 

Supply voltage 

: 12V to 24V DC +30% / -10% 

Power consumption 

: < 2W (VA) 

Output (electronic relay) 

Max. current 

Max. voltage 

 

: 250 mA 

: 50 VDC/VAC 

Temperature range 

: -20°C to +55°C 

Norm Conformity 

: R&TTE 1999/5/EC; EMC 2004/108/EC 

Degree of protection 

: IP54 

Material 

: ABS & Polycarbonate 

Color of head housing 

: black smoked, aluminum 

Dimensions 

: 80 mm (W) x 60 mm (H) x 55 mm (D) 

Weight 

: 140g 

Length of cable 

: 2.5m 

Specifications are subject to changes without prior notice 

The declaration of conformity is available on our website: www.faac.it 

 
 
 
 
 

 
 
 

SYMPTOMS 

POSSIBLE  CAUSES 

CORRECTIVE ACTION 

 

The door will not open and no red LED 
lights up. 

 

The sensor power is off. 

 

Check the wiring and the power supply. 

The door opens and closes constantly.  1. The sensor "sees" the door moving. 

Increase the tilt angle and/or reduce the sensitivity. 

 

2. Closing the door creates vibrations 
picked up by the sensor. 

Ensure that the sensor is correctly fixed. 
 

The door will not close. 
Red LED OFF 

1. On-Off switch at door control is in 
wrong position or faulty. 

Make sure that On-Off switch for door is in the ON or 
AUTOMATIC position.  

 

2. Improper output configuration 

Check the output configuration setting on each sensor 
connected to the door operator. 