1
2
0
1
2
1
2
0
1
2
3
3
0
1
2
1
2
0
1
2
3
3
0
1
0
1
2
«click»
1
1
H
W
H
W
2 m
1 m
max.
5 cm
max. 5 cm
+
-
+
-
MOUNTING & WIRING
INFRARED FIELD - SAFETY
GREEN
BROWN
YELLOW
WHITE
PINK
GREY
RED
2
BLUE
2
POWER SUPPLY
OPENING INPUT
SAFETY INPUT
TEST
OUTPUT
WIDTH
RED
LED
1
Output status when sensor is operational
2
For compliance with EN 16005, connection
to door controller test output is required.
The door control unit and the door cover profi le must be correctly earthed.
S
E
NS
OR
H
W
2.20 m 2.30 m
2.50 m 2.55 m
3.00 m 2.80 m
H
W
2.20 m 1.20 m
2.50 m 1.40 m
3.00 m 1.60 m
Depth of curtain: 8-10 cm
Depth of safety fi eld: 25 cm*
RELAY R1
RELAY R2
12-30 V DC
Check position of IR-curtains with
Spotfi nder and adjust if necessary.
DOOR
Detection fi eld width indicated according to conditions defi ned in EN 16005 and including dimension of test body CA.
A
vailable as accessory
ANGLE
CLOSER
CLOSER
AWAY
AWAY
ORANGE
* in standard presetting
The size of the detection fi eld varies according to the mounting height of the sensor.
3
4
+
+
A
B
Launch an
ASSISTED SETUP
to verify wiring, position of the
curtains and correct functioning of the sensor.
SETTINGS
(by DIP-switch)
QUICK SETUP
ASSISTED SETUP
SETUP
OPEN+CLOSE
RED-GREEN
OFF
RED-GREEN
OFF
Step outside of the detection fi eld before launching a setup.
LONG (> 3s)
LONG
SHORT
standard
critical
environment
standard
extreme
1
1
Enhanced IR-immunity which excludes EN 16005-conformity of the door. system.
LONG (> 3s)
critical environment
: enhanced immunity for critical environments (rain, snow, lamps...). Only 1 IR-curtain activated.
standard
: standard environments (factory setting)
NC
NO
The yellow and white wires have to be connected to launch an
assisted setup.
After changing a DIP-switch, the orange LED fl ashes.
A LONG push on the push button confi rms the setting.
Always launch a setup after changes of the DIP-settings.
- Test the good functioning of the installation before leaving the premises.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery
directive 2006/42/EC.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer
of the sensor.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualifi ed personnel may install and setup the sensor.
- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to
neon lamps or moving objects.
- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
SAFETY INSTRUCTIONS
PRESETTINGS
ENVIRONMENT
R2 CONFIGURATION
FREQUENCY
ORANGE
OFF