2
1
4
5
1
2
1
1
2
1
2
1
2
1
2
1
1
2
1
2
1
1
1
1
2
FAAC S.p.A . - Via Calari, 10 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com
Manufactured by: BEA SA - LIEGE Science Park - Allée des Noisetiers 5 - 4031 Angleur - Belgium - T +32 4 3616565 - F +32 4 3612858 - [email protected] - www.bea.be
©
BE
A
|
O
ri
g
ina
l ins
tr
u
c
ti
o
ns
|
42
.7
85
9
/
V1
-
06
.1
3
BEA hereby declares that the FAAC XBFA ON is in conformity with the basic requirements and the other relevant provisions
of the directives 2004/108/EC and 2006/42/EC.
Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
Angleur, June 2013
Pierre Gardier, Authorized representative and responsible for technical documentation
LED-SIGNALS
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
P
L
E
A
S
E
K
E
E
P
F
O
R F
U
R
T
H
E
R U
S
E - D
E
S
IG
N
E
D
F
O
R C
O
LO
U
R
P
R
IN
T
IN
G
The ORANGE LED
fl ashes 1 x.
The ORANGE LED
fl ashes 2 x.
The ORANGE LED
fl ashes 4 x.
The ORANGE LED
fl ashes 5 x.
The ORANGE LED
is on.
The RED LED fl ashes
quickly after an
assisted setup.
The RED LED
lights up
sporadically.
The LED is off.
The reaction of
the door does not
correspond to the
LED-signal.
The ORANGE LED
fl ashes quickly.
The sensor signals
an internal fault.
Irregularities in the
power supply
The sensor receives
not enough IR-energy.
The sensor receives
too much IR-energy.
The sensor encounters
a memory problem.
The sensor vibrates.
The sensor sees the door
during the assisted setup.
The sensor sees the door.
The sensor is disturbed by
lamps or another sensor.
The sensor is disturbed
by the rain.
A DIP-switch was changed
without confi rmation.
Check power supply.
Check wiring.
Use the 1 m prism if possible (accessory).
Check the angle of the IR-curtains.
Cut and restore power supply.
If orange LED lights up again, replace sensor.
Check the angle of the IR-curtains.
Launch a new assisted setup.
Attention: Do not stand in the detection fi eld!
Change the output confi guration (DIP 4).
Use a low energy prism if possible (accessory).
Check the angle of the IR-curtains.
Check if the sensor is fastened fi rmly.
Check position of prism and cover.
Choose a different frequency (DIP 2).
Choose the critical environment presetting (DIP 1).
Launch an assisted setup and adjust the IR angle.
Cut and restore power supply.
If orange LED fl ashes again, replace sensor.
Check connections to test output.
If your door controller is not able to test the sensor,
connect the red and blue cable to the power supply.*
Confi rm the DIP-settings by a long push on the
push button.
*excludes EN 16005-conformity of the door system
XBFA ON
1
2
6
3
4
5
1. cover
2. IR-prism
(2 m)
3. main
connector
DESCRIPTION
ENGLISH
Safety sensor
for automatic sliding doors
4. IR-angle
adjustment
5.
push button for setup or DIP-setting confi rmation
6. DIP-switch
User’s Guide for product version 0100 and higher
See product label for serial number
TECHNICAL SPECIFICATIONS
Presence
Typical response time: <256 ms
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
Solid-state-relay
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s to 1 s (not adjustable)
Typical: < 5 ms
12 V - 30 V DC -5%/+10%
(to be operated from SELV compatible power supplies only)
< 1.6 W
1.8 m to 3 m
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
< 70 dB
20 years
MD 2006/42/EC; ROHS 2 2011/65/EU; EN 16005:2012; EN 12978:2009;
EN IEC 62061:2005 SIL2; EN 61496-1:2012 ESPE Type 2; EN ISO 13849-1:2008 Pl «c»
CAT.2
(under the condition that the door control system monitors the sensor at least once per door cycle)
Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Norm conformity:
Detection mode:
Technology:
Angle:
Output:
Hold time output signal:
Response time on test request:
Specifi cations are subject to changes without prior notice. All values measured in specifi c conditions.
RED